一、WBYD2000調頻式串聯諧振變壓器基本原理
耐壓試(shi)驗是利(li)用電抗器的電感與被(bei)試(shi)品電容(rong)組成LC串聯回路,調節變頻電源輸(shu)出的電壓頻率(lv),在被(bei)試(shi)品上獲得高(gao)電壓,是當前(qian)高(gao)電壓試(shi)驗的一種新(xin)方法,深受專(zhuan)家好(hao)評,在國(guo)內外已經得到廣(guang)泛的使用。
根據諧振原理(li),我們知道(dao)當(dang)電抗器L的感抗值(zhi)Xl與回(hui)路(lu)(lu)中的容抗值(zhi)Xc相等(deng)時,回(hui)路(lu)(lu)達(da)到諧振狀態,此時回(hui)路(lu)(lu)中僅回(hui)路(lu)(lu)電阻R消耗有功功率,而無功功率則在電抗器與試(shi)品電容之間(jian)來(lai)回(hui)振蕩,從而在試(shi)品上產生高壓。
二、WBYD2000調頻式串聯諧振變壓器系統構成
全(quan)套試驗系(xi)統(tong)由調頻電源主機、電抗(kang)器(qi)、分壓(ya)器(qi)、激勵(li)變壓(ya)器(qi)和補償(chang)電容器(qi)(可選器(qi)件(jian))組(zu)成(cheng),接入(ru)被試品后組(zu)成(cheng)一個諧振系(xi)統(tong)進行(xing)交(jiao)流耐壓(ya)實驗。
主機: 就是(shi)一臺幅值和(he)頻(pin)率可(ke)調的正弦波交流調頻(pin)電(dian)源,給諧振回路(lu)提供(gong)激勵源,同時(shi)提供(gong)電(dian)壓顯示(shi)、電(dian)流顯示(shi)、計時(shi)、保護(hu)、報(bao)警等功能(neng)。
電抗器(qi):就是一(yi)個(ge)大電感(gan)(gan)線圈(quan),與(yu)被試品(相當于電容)構成回(hui)路,可配置電抗器(qi)多節電抗器(qi),使用時通過(guo)不(bu)同(tong)的串聯、并(bing)聯組(zu)合、實現(xian)不(bu)同(tong)的電感(gan)(gan)量以適(shi)用不(bu)同(tong)的試驗條件(jian)。
分(fen)壓(ya)(ya)器(qi):內部通過電容器(qi)分(fen)壓(ya)(ya),從試品上高(gao)電壓(ya)(ya)分(fen)得(de)低電壓(ya)(ya)供主機測量、控制使用。
勵磁變壓器:隔離主機(ji)電(dian)源與諧振回路電(dian)源,并升高(gao)主機(ji)的輸出電(dian)壓。
補(bu)償電容(rong)器:當試品電容(rong)量(liang)很小時(shi),如果要實現系統諧振可能要求的(de)(de)電源頻率超(chao)出試驗標準的(de)(de)規定,可在試品上(shang)并聯一個補(bu)償電容(rong),以實現試驗要求,稱此電容(rong)器為補(bu)償電容(rong)器。
三、WBYD2000調頻式串聯諧振變壓器主要技術性能
功(gong)率電源電壓:AC380V±10%、50Hz;
儀器電源:220V±10%、50Hz;
諧振輸出容(rong)量:200kVA;
儀器額定(ding)電壓:0~200kV;
輸(shu)出頻率(lv)范(fan)圍:30~300Hz;
輸出電(dian)壓波(bo)形:正(zheng)弦(xian)波(bo),波(bo)形畸變率<0.5%;
頻(pin)率調節靈敏度:0.1Hz,不穩定度≤0.05%;
系統(tong)噪聲:≤60db;
9、系統測量精度:<1級(ji);
10.輸出(chu)電壓不(bu)穩定:<0.5%;
11.保護響應時間:1us;
12.電(dian)感非線性度:≤0.05%;;
13.滿功率輸出下,連續工(gong)作(zuo)時間為60min
14.環境溫度:-15℃~+50℃;
15.相對(dui)濕度:≤90%RH;
16.海拔高(gao)度:≤2000米。
四、WBYD2000調頻式串聯諧振變壓器面板及部件名稱
五、WBYD2000調頻式串聯諧振變壓器操作步驟
1、正(zheng)確連線,檢查(cha)無誤后方可送電。
必(bi)要時工作電(dian)源的跳過(guo)現場(chang)漏電(dian)保安器,以(yi)免(mian)不必(bi)要的跳閘。
2、打開電(dian)源開關,主機(ji)開始工作,液(ye)晶屏顯示(shi)版(ban)權頁,該頁標明本(ben)裝置的軟件版(ban)本(ben)號。
觸(chu)按確認鍵,進入系(xi)統(tong)菜單,該主菜單下有:試驗(yan)方案、開始試驗(yan)、試驗(yan)幫助(zhu)、系(xi)統(tong)設置、實用工具和試驗(yan)記錄等(deng)六個(ge)子(zi)菜單項。
3、 系(xi)(xi)統(tong)設(she)置菜(cai)單(dan)下有電(dian)(dian)(dian)抗(kang)(kang)器電(dian)(dian)(dian)感(gan)、日期時(shi)間(jian)設(she)置和(he)采樣(yang)系(xi)(xi)數(shu)設(she)置等三個(ge)子菜(cai)單(dan)項(xiang)。按(an)(an)上下鍵(jian),上下移動光標系(xi)(xi)統(tong)參(can)數(shu)設(she)置菜(cai)單(dan)項(xiang),觸(chu)按(an)(an)確定(ding)(ding)鈕后,進入系(xi)(xi)統(tong)參(can)數(shu)設(she)置菜(cai)單(dan),可以分別設(she)定(ding)(ding)電(dian)(dian)(dian)抗(kang)(kang)器的電(dian)(dian)(dian)感(gan)—H、-年-月-日、-時(shi)-分-秒(miao)和(he)電(dian)(dian)(dian)壓(ya)和(he)電(dian)(dian)(dian)流(liu)的采樣(yang)系(xi)(xi)數(shu)也(ye)就是采樣(yang)倍率(lv),設(she)定(ding)(ding)完成(cheng)后,觸(chu)按(an)(an)返還鍵(jian)返回上**菜(cai)單(dan)。
電(dian)抗(kang)器電(dian)感量的設定:按(an)確定鍵(jian)(jian)選擇到此項,按(an)左右鍵(jian)(jian)移動光標(biao)需要(yao)改變的數位(wei),按(an)上(shang)下鍵(jian)(jian)改變數值,達到所要(yao)達到的數值按(an)確定鍵(jian)(jian)確認。
日(ri)期時間(jian)的(de)設(she)(she)定:按(an)確定鍵選擇(ze)到(dao)此項,按(an)左右鍵移動光標需(xu)要改變的(de)數位,按(an)上下鍵改變數值,按(an)照(zhao)所要設(she)(she)置的(de)年月日(ri)時間(jian)數值按(an)確定鍵確認。
采樣(yang)系數(shu)的(de)設定(ding):按(an)確定(ding)鍵選擇(ze)到高(gao)壓(ya)/電(dian)(dian)流采樣(yang)系數(shu)項,此項為電(dian)(dian)壓(ya)或電(dian)(dian)流采樣(yang)倍率的(de)設定(ding)。一(yi)般出廠前設定(ding)好(hao)了。如需修改,要輸入密碼。(密碼廠家(jia)與設備一(yi)起提供一(yi)般設定(ding)為:188888)
警告:系統默認上一次電(dian)(dian)(dian)(dian)(dian)(dian)抗器電(dian)(dian)(dian)(dian)(dian)(dian)感、日(ri)期時間和采樣系數(shu)設(she)(she)定值。如果需(xu)改變要(yao)重新設(she)(she)定。電(dian)(dian)(dian)(dian)(dian)(dian)抗器電(dian)(dian)(dian)(dian)(dian)(dian)感量(liang)設(she)(she)定值與實際(ji)使用(yong)的電(dian)(dian)(dian)(dian)(dian)(dian)抗器電(dian)(dian)(dian)(dian)(dian)(dian)感量(liang)不(bu)對(dui),會導致(zhi)試(shi)驗報告中的被試(shi)品電(dian)(dian)(dian)(dian)(dian)(dian)容量(liang)不(bu)準(zhun)。其他并不(bu)會影(ying)響。采樣系數(shu)設(she)(she)置不(bu)正確,會導致(zhi)顯示(shi)電(dian)(dian)(dian)(dian)(dian)(dian)壓電(dian)(dian)(dian)(dian)(dian)(dian)流不(bu)準(zhun)將很有可能會對(dui)被試(shi)品或試(shi)驗設(she)(she)備造成損(sun)壞。
4、試(shi)驗(yan)方案菜單(dan)下有預(yu)置(zhi)保護電流、找頻(pin)(pin)起(qi)始(shi)頻(pin)(pin)率(lv)、找頻(pin)(pin)結束(shu)頻(pin)(pin)率(lv)、預(yu)定(ding)(ding)起(qi)始(shi)功(gong)率(lv)四個子菜單(dan)項,分別設定(ding)(ding)本次試(shi)驗(yan)的保護電流、找頻(pin)(pin)起(qi)始(shi)頻(pin)(pin)率(lv)、找頻(pin)(pin)結束(shu)頻(pin)(pin)率(lv)、輸出起(qi)始(shi)功(gong)率(lv),全部設定(ding)(ding)完成后(hou),觸按返(fan)還鍵進入預(yu)置(zhi)試(shi)驗(yan)電壓和預(yu)置(zhi)試(shi)驗(yan)時間設置(zhi)菜單(dan)。
可以分(fen)(fen)3段時間設(she)置試(shi)驗(yan)電壓(ya)和試(shi)驗(yan)時間, 實際試(shi)驗(yan)時,若(ruo)設(she)定為自動試(shi)驗(yan), 裝置將(jiang)按設(she)定的3段電壓(ya)及時間,按順序(xu)分(fen)(fen)別加(jia)壓(ya), 全部完成后(hou)自動退(tui)出.
如果**段電(dian)壓設(she)為0, 或時間(jian)設(she)為0, 那么執行完**段試驗電(dian)壓加壓后退出試驗, 只加壓**段設(she)定的(de)電(dian)壓.
如果第(di)三段電壓(ya)設為0, 或時間設為0, 不執行第(di)三段加(jia)壓(ya).
試(shi)(shi)驗(yan)方(fang)案設(she)(she)置的(de)(de)設(she)(she)定(ding)(ding):在試(shi)(shi)驗(yan)電壓項中,按確定(ding)(ding)單鈕,移動左右光標到需要(yao)改變的(de)(de)數位(wei),按上下單鈕以改變當前數位(wei)的(de)(de)數值(zhi)大(da)小,觸按返(fan)回(hui)鈕完(wan)成當前數位(wei)的(de)(de)數值(zhi)設(she)(she)定(ding)(ding),依次選擇(ze)下一(yi)項數值(zhi)的(de)(de)設(she)(she)定(ding)(ding),直至分別(bie)完(wan)成試(shi)(shi)驗(yan)時(shi)間、起始(shi)頻(pin)率(lv)(lv)、起始(shi)功率(lv)(lv)的(de)(de)設(she)(she)置,方(fang)可完(wan)成本次試(shi)(shi)驗(yan)的(de)(de)試(shi)(shi)驗(yan)方(fang)案設(she)(she)置的(de)(de)設(she)(she)定(ding)(ding)。
出廠默認值(zhi):試(shi)驗電(dian)壓 20kV、加壓時間 2min、激勵強度 2%、輸出電(dian)流20A、頻率范(fan)圍30-300Hz。
5、實用工具菜單(dan)下有
頻(pin)率計算:在(zai)實驗(yan)前可對諧振頻(pin)率進行計算。只(zhi)需(xu)輸入具體參(can)與試(shi)驗(yan)的(de)電感、電容值并按確(que)定鍵試(shi)驗(yan)頻(pin)率即(ji)直接生成。
6、開始試(shi)驗(yan)(yan)菜(cai)單下有自動(dong)試(shi)驗(yan)(yan)模式(shi)和手(shou)動(dong)試(shi)驗(yan)(yan)模式(shi)兩(liang)種子菜(cai)單可供(gong)選擇。
按確認鍵進入所選試(shi)驗(yan)步驟.
自動(dong)試(shi)驗模(mo)式的操作:選中自動(dong)試(shi)驗模(mo)式后(hou),觸按菜單鈕進入正(zheng)在自動(dong)尋找諧(xie)振點菜單項(xiang),裝(zhuang)置在設定的頻(pin)(pin)(pin)(pin)率(lv)(lv)范(fan)圍內自動(dong)尋找諧(xie)振點(如果(guo)被(bei)試(shi)品(pin)電容C和電抗(kang)器電感L的實際諧(xie)振頻(pin)(pin)(pin)(pin)率(lv)(lv)不(bu)(bu)在設定的頻(pin)(pin)(pin)(pin)率(lv)(lv)范(fan)圍內,將找不(bu)(bu)到(dao)諧(xie)振點,此(ci)時根(gen)據需要(yao)調整頻(pin)(pin)(pin)(pin)率(lv)(lv)范(fan)圍或調整被(bei)試(shi)品(pin)回路(lu)的LC參數)。當找到(dao)諧(xie)振點時,會有(you)聲音提示。
找到諧振(zhen)點后,裝(zhuang)置自動進(jin)入正在自動升壓菜單項,當升到試驗電(dian)壓設定的電(dian)壓時,裝(zhuang)置停止加壓。
當(dang)裝(zhuang)置(zhi)升到(dao)試(shi)(shi)驗(yan)(yan)電(dian)壓(ya)(ya)設(she)定的電(dian)壓(ya)(ya)時(shi),設(she)備停止加(jia)壓(ya)(ya),自動進(jin)(jin)入(ru)正在加(jia)壓(ya)(ya)試(shi)(shi)驗(yan)(yan)菜單(dan)項,并自動記錄試(shi)(shi)驗(yan)(yan)的加(jia)壓(ya)(ya)時(shi)間,當(dang)加(jia)壓(ya)(ya)時(shi)間到(dao)達設(she)定時(shi)間時(shi),設(she)備逐步(bu)降壓(ya)(ya)退出試(shi)(shi)驗(yan)(yan),完(wan)成本次試(shi)(shi)驗(yan)(yan),進(jin)(jin)入(ru)試(shi)(shi)驗(yan)(yan)結束菜單(dan)項。并可(ke)選擇保存試(shi)(shi)驗(yan)(yan)數據或打印試(shi)(shi)驗(yan)(yan)數據。
試驗(yan)(yan)時(shi)間(jian)的一(yi)(yi)行顯(xian)示末端,會顯(xian)示[一(yi)(yi)段(duan)]或[二(er)段(duan)]或[三段(duan)]字樣(yang),表示當前正在進行的加壓(ya)試驗(yan)(yan)是預置(zhi)的一(yi)(yi)段(duan),二(er)段(duan)或三段(duan).
手動(dong)試(shi)(shi)驗(yan)模(mo)式(shi)的(de)(de)操作(zuo):選中手動(dong)試(shi)(shi)驗(yan)模(mo)式(shi)后觸按確定鈕,進入(ru)正在試(shi)(shi)驗(yan)菜單(dan)項;手動(dong)按調(diao)頻(pin)鈕,對應的(de)(de)光標(biao)隨之改變(bian)到(dao)輸出頻(pin)率項,可以通(tong)過上下(xia)左(zuo)右鍵改變(bian)頻(pin)率大小使其試(shi)(shi)驗(yan)電壓(ya)(ya)逐(zhu)步升高,當(dang)升到(dao)*高電壓(ya)(ya)時(shi),繼續向(xiang)上或向(xiang)下(xia)調(diao)整(zheng)頻(pin)率按鈕,直至試(shi)(shi)驗(yan)電壓(ya)(ya)開始下(xia)降;這(zhe)時(shi)反調(diao)頻(pin)率,試(shi)(shi)驗(yan)電壓(ya)(ya)又逐(zhu)步回升,上下(xia)回調(diao)頻(pin)率,從頻(pin)率的(de)(de)高位(wei)(wei)到(dao)低位(wei)(wei)逐(zhu)位(wei)(wei)調(diao)整(zheng)*高電壓(ya)(ya)值時(shi)的(de)(de)頻(pin)率就是當(dang)前的(de)(de)諧(xie)振頻(pin)率。
找到諧振點后(hou),手(shou)動按(an)電(dian)壓(ya)鈕,光標到了輸(shu)出(chu)功率,隨(sui)之(zhi)按(an)上下(xia)鍵增加輸(shu)出(chu)功率,試(shi)(shi)(shi)驗(yan)電(dian)壓(ya)也逐(zhu)步(bu)升高,當升到試(shi)(shi)(shi)驗(yan)電(dian)壓(ya)設(she)定電(dian)壓(ya)值時(shi),裝置停止加壓(ya),并(bing)有屏幕(mu)顯示(shi)提(ti)示(shi)和(he)聲音提(ti)示(shi);自動進(jin)入正在加壓(ya)試(shi)(shi)(shi)驗(yan)菜(cai)單(dan)項,并(bing)自動記錄試(shi)(shi)(shi)驗(yan)的加壓(ya)時(shi)間,當到達加壓(ya)時(shi)間設(she)定時(shi)間時(shi),設(she)備(bei)逐(zhu)步(bu)降壓(ya)退出(chu)試(shi)(shi)(shi)驗(yan),完成(cheng)本(ben)次試(shi)(shi)(shi)驗(yan),進(jin)入試(shi)(shi)(shi)驗(yan)結束菜(cai)單(dan)項。
注(zhu)意:在(zai)調節(jie)頻(pin)(pin)(pin)率調整鈕的(de)過程(cheng)中,觸(chu)(chu)按(an)(an)(an)左右(you)鈕,可以(yi)改變(bian)(bian)頻(pin)(pin)(pin)率調節(jie)的(de)速度(du)實現粗(cu)細(xi)調的(de)切(qie)換(huan)。在(zai)調節(jie)電(dian)(dian)壓(ya)調整鈕的(de)過程(cheng)中,向(xiang)下觸(chu)(chu)按(an)(an)(an)左右(you)鈕,可以(yi)改變(bian)(bian)電(dian)(dian)壓(ya)的(de)升降(jiang)的(de)速度(du)實現粗(cu)細(xi)調的(de)切(qie)換(huan)。觸(chu)(chu)按(an)(an)(an)調頻(pin)(pin)(pin)、調壓(ya)鈕,實現調頻(pin)(pin)(pin)與調壓(ya)間的(de)切(qie)換(huan)。
7、進入(ru)試驗記(ji)錄(lu)查(cha)詢(xun)(xun)菜單項,查(cha)詢(xun)(xun)以(yi)往(wang)和當(dang)前試驗數據。選擇上下鍵(jian)翻(fan)看前一組數據后一組數據;選擇左右鍵(jian)可選擇打印(yin)或刪除當(dang)前頁的內容。
125/456為(wei)試(shi)驗(yan)數(shu)據庫指針,分(fen)子(zi)是試(shi)驗(yan)數(shu)據的在數(shu)據庫的順(shun)序數(shu),分(fen)母是當前的數(shu)據總數(shu),*多可儲存999組試(shi)驗(yan)數(shu)據。
8、裝置(zhi)和(he)試驗(yan)狀態菜單提示:設(she)備的(de)使用和(he)升(sheng)壓和(he)耐壓試驗(yan)過(guo)程中(zhong),如果出現影(ying)響試驗(yan)設(she)備、被試驗(yan)設(she)備以及操作人的(de)**情(qing)況,設(she)備可能出現自(zi)動保(bao)護轉臺,并在屏幕有相應的(de)提示。
不(bu)(bu)能(neng)諧振:如果諧振點(dian)不(bu)(bu)在諧振頻率設置的范圍內(nei);系統連線不(bu)(bu)正(zheng)確等現象,裝置將(jiang)找不(bu)(bu)到諧振點(dian),這時裝置和試驗狀態菜(cai)單中的不(bu)(bu)能(neng)諧振項被反(fan)白并閃(shan)爍。
輸出(chu)保護:如果(guo)裝(zhuang)置的(de)電(dian)源輸出(chu)電(dian)流大于輸出(chu)保護設(she)定的(de)電(dian)流值,裝(zhuang)置自(zi)動保護,這時(shi)裝(zhuang)置和試驗狀態菜單(dan)中的(de)輸出(chu)保護項(xiang)被反(fan)白并(bing)閃爍。
試(shi)驗中止:如果在試(shi)驗升壓(ya)或加(jia)壓(ya)過程出(chu)現閃(shan)(shan)絡現象(xiang),裝置自(zi)動保(bao)護,這時裝置和(he)試(shi)驗狀態(tai)菜單中的輸出(chu)保(bao)護項(xiang)被(bei)反(fan)白(bai)并閃(shan)(shan)爍。
9、試驗幫助內容(rong)包括五大項分別為:1.版本信息2.接線(xian)示意3.使用說明(ming)4.常見問題5.參考資料.如(ru)常見問題FAQ分五幅(fu)畫(hua)面顯示、各種(zhong)被(bei)試品電(dian)力電(dian)纜(lan)、變壓器、發電(dian)機電(dian)容(rong)參數的查詢:
接線示意圖(tu):
10、設備(bei)出(chu)廠(chang)參(can)數設置是(shi)生產廠(chang)家(jia)的出(chu)廠(chang)設置參(can)術和校驗參(can)數,不(bu)適當的設置和修(xiu)改(gai)會影響設備(bei)性(xing)能(neng)和高壓試驗的**性(xing),未經廠(chang)家(jia)授權密碼,無(wu)法修(xiu)改(gai)。
警告:正常(chang)試驗狀(zhuang)態下(xia)(xia),按返回鍵即可中止試驗。中止或(huo)結束試驗后(hou),應分離(li)刀閘切斷(duan)電(dian)源。在升壓或(huo)加壓過程(cheng)中,非緊急情況,不要按下(xia)(xia)急停鍵。
六、本說明書的(de)專屬名(ming)詞的(de)定義
自動(dong)試驗:高壓(ya)試驗全過(guo)程(cheng)(cheng)由主機按程(cheng)(cheng)序和(he)預置參數自動(dong)完成。
自動(dong)調諧:調諧由主(zhu)機按程序自動(dong)完(wan)成(cheng),升壓手動(dong)完(wan)成(cheng)。
手動試驗:尋找諧振(zhen)點和升壓均為手動,通過面板旋鈕完成。
系統參數設(she)置是(shi)指對(dui)設(she)備部件參數的(de)設(she)置。
試驗參(can)數設置(zhi)是指對(dui)試驗過程參(can)數的設置(zhi)。
試驗模(mo)式選(xuan)(xuan)擇(ze)是(shi)指(zhi)對(dui)試驗模(mo)式的選(xuan)(xuan)擇(ze)。
試驗結果查詢是指對(dui)試驗數(shu)據(ju)的查詢。
分(fen)壓(ya)器(qi)變比是(shi)指對分(fen)壓(ya)器(qi)的分(fen)壓(ya)比設(she)置。
電抗器電感是指對電抗器電抗值的設置。
激勵(li)變(bian)(bian)(bian)變(bian)(bian)(bian)比(bi)是指對勵(li)磁變(bian)(bian)(bian)壓器的變(bian)(bian)(bian)比(bi)設(she)置。
設(she)置電壓是高(gao)壓試(shi)驗(yan)時(shi)的保(bao)護電壓設(she)置。
試驗(yan)電(dian)壓(ya)是高壓(ya)試驗(yan)時的試驗(yan)電(dian)壓(ya)。
加壓(ya)時(shi)間是施加試驗(yan)電壓(ya)的(de)時(shi)間。
激勵強度是(shi)指主機電(dian)源輸出的大小。
輸(shu)出電流(liu)是(shi)主機電源的輸(shu)出電流(liu)。
頻率范圍是(shi)試驗的頻率范圍。
自動(dong)試驗模(mo)式是指試驗過程全部自動(dong)完成。
自(zi)動(dong)調諧模(mo)式是指自(zi)動(dong)尋找(zhao)諧振(zhen)點后,手動(dong)加壓完成試(shi)驗。
手動試驗(yan)模式全部由人工完成(cheng)試驗(yan)過(guo)程。
未接地線主機(ji)電源為接地。
不能(neng)諧振未(wei)能(neng)找到諧振點。
輸出保(bao)護主機(ji)電(dian)(dian)(dian)源輸出電(dian)(dian)(dian)流(liu)大于整定(ding)電(dian)(dian)(dian)流(liu)。
試驗(yan)中止指在升壓或加(jia)壓過程裝置自動保護。
設(she)備出廠參數設(she)置是(shi)廠家(jia)對設(she)備有(you)關參數的設(she)置。
確(que)認(ren)鍵:確(que)認(ren)當(dang)前操作(zuo)。
返(fan)回鍵:返(fan)回上**菜單。
七、變頻電源技術參數:
1.額(e)定輸出容量:15kvA;
2.儀器(qi)電(dian)源(yuan):220v±10% 50Hz;
功率電源(yuan):380v±10% 50Hz;
3.額(e)定輸(shu)入電流:39.5A;
4.額定輸(shu)出(chu)電壓(ya):0-340v可調(diao)、單相、輸(shu)出(chu)電壓(ya)不穩定度0.05%;
5.額定輸(shu)出電流:44A;
6.頻率調節(jie)范圍:25~320Hz;
7.額定(ding)容量下連續運行為規(gui)定(ding)工(gong)作時(shi)間下*高溫升≤60K;
8.顯示以下參(can)數:
a.經變(bian)頻輸出的頻率、電(dian)(dian)壓(ya)、電(dian)(dian)流;
b.過壓(ya)保護(hu)電壓(ya)值(zhi),并可(ke)任意(yi)整(zheng)定(ding)(ding),當成(cheng)套裝置(zhi)的輸出電壓(ya)值(zhi)達到保護(hu)整(zheng)定(ding)(ding)時,可(ke)自動切除成(cheng)套裝置(zhi);
c.過流(liu)保護(hu):當(dang)調頻(pin)電源的輸出電流(liu)達(da)到保護(hu)整(zheng)定值時,可自動切除成套裝置;
d.擊穿保(bao)(bao)護(hu):當(dang)高壓側發生(sheng)對地(di)閃(shan)絡(luo)時,可(ke)自動切除成(cheng)套裝置(zhi),裝置(zhi)帶有隔離(li)裝置(zhi),可(ke)確保(bao)(bao)設備和(he)人身不受(shou)損害;
e.具有全電(dian)壓輸(shu)出保護,在(zai)調(diao)(diao)壓過程中,一旦調(diao)(diao)壓失控,調(diao)(diao)頻電(dian)源立即閉鎖(suo);
9.可實現(xian)以(yi)下操(cao)作:
a.頻率(lv)的(de)調節(jie),上升和(he)下降頻率(lv)調節(jie)分粗(cu)調和(he)細調兩種,并(bing)可自動尋找(zhao)試驗諧振(zhen)點,保(bao)證諧振(zhen)頻率(lv)在整個(ge)試驗過程中(zhong)不發(fa)生漂移(yi);
b.帶有設置電(dian)壓、設置時間,電(dian)壓自動(dong)上升到(dao)設置值而停(ting)止并自動(dong)計時;
c.帶(dai)有各種保護功能(neng)的(de)整定(ding)按(an)鈕,可在面板上對(dui)各種保護值進行整定(ding);
d.帶(dai)有手動(dong)試(shi)驗(yan)功能和自動(dong)試(shi)驗(yan)功能;
e.帶有試(shi)驗數據(ju)打印功(gong)能。
八、勵磁變壓(ya)器技術參數:
1.結構形式:干式;
2.額定容量(liang):15kVA;
3.輸入電壓:0~340V;
4.輸(shu)出電(dian)壓:四組并聯(lian)3.75KV;四組串聯(lian)15KV;二串二并7.5KV;
5.輸出電流:四組并聯4A;四組串(chuan)聯1A;二串(chuan)二并2A;
6.工作頻(pin)率范圍:30~300Hz;
勵磁(ci)變壓器的接線(xian)端子(zi),如圖所示:
1.輸出端(duan)尾—與接(jie)地端(duan)連接(jie)。
2.輸出(chu)端頭—與電抗(kang)器(qi)連接(jie)。
3.接地端(duan)—與變(bian)頻電源(yuan)、分壓器及被試品共(gong)同(tong)接地。
4.輸入端—接調頻(pin)電源(yuan)功率(lv)輸出端。
九、諧(xie)振電抗器技術參數:
額定容量:55KVA;
額定(ding)電壓:55kV;
額定(ding)電(dian)流:1.5A;
電(dian) 感 量(liang):160H;
品(pin)質因(yin)數:Q≥30
采(cai)用(yong)環氧干式。
7.接線端了如圖(tu)所示:
a.高(gao)壓(ya)側(ce)接(jie)線端子(zi)—與(yu)被(bei)試品高(gao)壓(ya)端連(lian)接(jie)。
b.低(di)壓(ya)側接線端子—與勵磁變輸出(chu)端連(lian)接。
c.多臺電(dian)抗(kang)器串(chuan)聯(lian)(lian)時上(shang)節的低壓(ya)側與下節高壓(ya)側連接。諧振電(dian)抗(kang)器采用(yong)多臺串(chuan)聯(lian)(lian)或(huo)并聯(lian)(lian)的連接方式。
8.額(e)定(ding)容量下(xia)連續(xu)運行為規定(ding)工作時間下(xia),電抗器對(dui)空氣的溫(wen)升不大于60K;
9.性(xing)能(neng)及特點:電抗器(qi)設計干式、環氧澆鑄,電抗器(qi)可以自(zi)由(you)方(fang)便疊(die)裝(zhuang)。環氧樹脂絕(jue)緣筒外(wai)殼,具有足夠的電氣、機械(xie)強度,必要的散熱能(neng)力(li)以及油熱脹冷縮(suo)的裕度。外(wai)殼上(shang)下蓋板,顏色(se)為橘(ju)紅色(se)。
十(shi)、電容分壓器技術參數:
額定電壓:200kV;
工作頻(pin)率(lv):30~300Hz;
分(fen)壓比:2000:1;
分壓(ya)比誤差(cha):1%;
電(dian)容分(fen)壓器接(jie)線端子如圖所(suo)示:
高(gao)(gao)壓端(duan)—與電抗器高(gao)(gao)壓側(ce)及被試品(pin)高(gao)(gao)壓側(ce)相連。
測(ce)(ce)量插(cha)座—采(cai)用專配(pei)的(de)測(ce)(ce)量電纜(lan)與控制箱(xiang)背(bei)板測(ce)(ce)量輸入(ru)端連接(jie)。
接(jie)地端—采用專配接(jie)地線(xian)按接(jie)線(xian)圖指示接(jie)地。
4.性能(neng)及特點:
a.額定電(dian)壓下(xia)可連續運行2小時。
b.在30~300Hz范圍內,其精度(du)和(he)穩定度(du)保(bao)持不(bu)變。
c.在20℃溫度(du)下電(dian)容分壓器介質損耗值≤0.0025
d.電容分壓器(qi)配有(you)支撐底架,具(ju)有(you)足(zu)夠的穩定性。
e.電壓(ya)測量通過專用測試引線引至調頻電源進行測量。
試驗接線(xian)圖:
110kv主(zhu)變、GIS試驗接線
35kv電纜試驗接(jie)線(xian)圖(tu)
10kv電纜(lan)試驗接(jie)線圖
十二(er)、設備保存和維護(hu)
1、存放于干燥、清(qing)潔場(chang)地,防止雨水、灰(hui)塵(chen)進入部件內(nei)部;
2、如若長期不(bu)使(shi)用(yong)(yong),正(zheng)常天(tian)氣至少2個月(yue)應通電(dian)一(yi)(yi)(yi)次(ci)時(shi)間不(bu)少于半(ban)小時(shi),雨(yu)季及潮濕期應每隔(ge)一(yi)(yi)(yi)個月(yue)通電(dian)一(yi)(yi)(yi)次(ci),通電(dian)時(shi)間半(ban)小時(shi),以驅除設備內的潮氣防(fang)止電(dian)子(zi)元器件的銹蝕,影響正(zheng)常使(shi)用(yong)(yong)。
3、定期(qi)檢查裝置各(ge)部件,確保各(ge)接(jie)頭緊固無松動(dong);
4、更(geng)換(huan)打(da)印(yin)紙(zhi),機(ji)器采用熱(re)敏打(da)印(yin)紙(zhi)并且是前換(huan)紙(zhi)式當(dang)需要換(huan)紙(zhi)時(shi)只要按POST鍵鈕打(da)印(yin)紙(zhi)艙(cang)門就會打(da)開(kai)可以將新打(da)印(yin)紙(zhi)裝入;
十三、常見(jian)故障(zhang)排除
故障現象
|
發 生(sheng) 原 因
|
排 除 方 法
|
找(zhao)不(bu)到諧(xie)振點
|
接(jie)線有誤。
輸(shu)出開(kai)關未開(kai),;
3、做GIS時(shi)PT二次回(hui)路未(wei)打開;
4、試品(pin)Q值(zhi)太低;
5、起始激勵功率太低;
6、試驗回路有短路現象;
7、找頻(pin)范圍(wei)不對(dui)。
|
退出(chu)試(shi)驗狀態(tai),合上輸(shu)出(chu)開關,檢查接(jie)線;打(da)開PT二次回路;
調高(gao)起(qi)始功率(∠30%);
用兆歐表測(ce)量試品絕(jue)緣
重新設置找頻范圍(wei)
|
諧振(zhen)后,電壓(ya)升不上(shang)去
|
1、試(shi)品(pin)Q值太低;
2、激勵電(dian)壓不(bu)夠;
3、電抗器(qi)底部有(you)鐵磁物體;
4、3次(ci)諧波諧振。
|
檢查試品;
改變(bian)激勵變(bian)壓(ya)器繞組(zu)接法(fa),提高勵磁電壓(ya)
絕緣筒架高電抗器或離開鐵(tie)磁物(wu)體。
|
主機(ji)自動(dong)復位
|
供(gong)電(dian)電(dian)源(yuan)容量(liang)不夠;
電(dian)源引線過長或(huo)線徑(jing)過小(xiao);
接頭(tou)處接觸**;
供電電壓波動;
按鍵死接觸。
|
增(zeng)加供電電源(yuan)容(rong)量;
換(huan)較粗導線(xian),減小導線(xian)長度;
檢查接頭;
減小供(gong)電電壓(ya)波(bo)動。
|
開機后線路(lu)跳閘
|
線(xian)路漏電保護器較為敏感(gan);
空氣開關容(rong)量(liang)不夠。
|
跨過漏(lou)電保護(hu)器或空氣開關的接(jie)線(xian);
改換較大容(rong)量的空氣開關。
|
電壓跌(die)落
|
試品放電或(huo)擊穿
|
檢查(cha)試(shi)品(pin)
|
輸出短路(lu)
|
電流(liu)超過本機限流(liu)值。
|
檢(jian)查接線(xian)和(he)試品(pin)。
|
試品(pin)電壓不準
|
分壓比設置錯誤或分壓器(qi)信號(hao)傳輸(shu)有問題。
|
重設分壓比或檢查(cha)分壓器接線。
|
電壓閃變
|
試驗電壓劇(ju)烈波動,變化率(lv)超過本機(ji)限定值。
|
檢查供電(dian)(dian)電(dian)(dian)源(yuan)電(dian)(dian)壓穩定(ding)性或試(shi)品參數的變化。
|
回路無電(dian)流
|
|
檢(jian)查接(jie)線(xian)和試品。
|
未接好地(di)線
|
|
檢查接地線和(he)地樁,按說(shuo)明書要(yao)求連接。
|
試品過電壓
|
手動升壓太(tai)快或失控。
|
改(gai)變調壓步距或改(gai)用自(zi)動升壓 。
|
系統不諧振(zhen)
|
接線有誤(wu)或(huo)試品Q值太低。
|
檢查接線(xian)和試品(pin)
|
十四、常(chang)用設備資料參考
交(jiao)聯(lian)聚乙烯(xi)電纜(lan)單位長度電容量
電纜(lan)導體(ti)截面積(平方毫(hao)米)
|
電(dian) 容 (μ/km)
|
YJV、YJLV
|
YJV、YJLV
|
YJV、YJV、YJLV
|
YJV、YJLV
|
YJV、YJLV
|
6/6kV、6/10kV
|
8.7/10kV、8.7/15kV
|
12/35kV
|
21/35kV
|
26/35kV
|
1×35
|
0.212
|
0.173
|
0.152
|
|
|
1×50
|
0.237
|
0.192
|
0.166
|
0.118
|
0.114
|
1×70
|
0.270
|
0.217
|
0.187
|
0.131
|
0.125
|
1×95
|
0.301
|
0.240
|
0.206
|
0.143
|
0.135
|
1×120
|
0.327
|
0.261
|
0.223
|
0.153
|
0.143
|
1×150
|
0.358
|
0.284
|
0.241
|
0.164
|
0.153
|
1×185
|
0.388
|
0.307
|
0.267
|
0.180
|
0.163
|
1×240
|
0.430
|
0.339
|
0.291
|
0.194
|
0.176
|
1×300
|
0.472
|
0.370
|
0.319
|
0.211
|
0.190
|
1×400
|
0.531
|
0.418
|
0.352
|
0.231
|
0.209
|
1×500
|
0.603
|
0.438
|
0.388
|
0.254
|
0.232
|
1×600
|
0.667
|
0.470
|
0.416
|
0.287
|
0.256
|
2、交聯聚乙烯電纜單位長(chang)度電容量
電纜導體截面積(平方毫米(mi))
|
電 容 (μF/km)
|
YJV、YJLV
|
YJV、YJLV
|
YJV、YJV、YJLV
|
YJV、YJLV
|
YJV、YJLV
|
6/6kV、6/10kV
|
8.7/10kV、8.7/15kV
|
12/35kV
|
21/35kV
|
26/35kV
|
3×35
|
0.212
|
0.173
|
0.152
|
|
|
3×50
|
0.237
|
0.192
|
0.166
|
0.118
|
0.114
|
3×70
|
0.270
|
0.217
|
0.187
|
0.131
|
0.125
|
3×95
|
0.301
|
0.240
|
0.206
|
0.143
|
0.135
|
3×120
|
0.327
|
0.261
|
0.223
|
0.153
|
0.143
|
3×150
|
0.358
|
0.284
|
0.241
|
0.164
|
0.153
|
3×185
|
0.388
|
0.307
|
0.267
|
0.180
|
0.163
|
3×240
|
0.430
|
0.339
|
0.291
|
0.194
|
0.176
|
3×300
|
0.472
|
0.370
|
0.319
|
0.211
|
0.190
|
3×400
|
0.531
|
0.418
|
0.352
|
0.231
|
0.209
|
3×500
|
0.603
|
0.438
|
0.388
|
0.254
|
0.232
|
3×600
|
0.667
|
0.470
|
0.416
|
0.287
|
0.256
|
3、交聯(lian)聚乙烯電纜單位長度電容量(liang)
電纜導體截面積(平(ping)方毫米)
|
電 容 (μF/km)
|
YJV、YJLV
|
YJV、YJLV
|
64/110kV
|
128/220kV
|
3×240
|
0.129
|
|
3×300
|
0.139
|
|
3×400
|
0.156
|
0.118
|
3×500
|
0.169
|
0.124
|
3×630
|
0.188
|
0.138
|
3×800
|
0.214
|
0.155
|
3×1000
|
0.231
|
0.172
|
3×1200
|
0.242
|
0.179
|
3×1400
|
0.259
|
0.190
|
3×1600
|
0.273
|
0.198
|
3×1800
|
0.284
|
0.297
|
3×2000
|
0.296
|
0.215
|
3×2200
|
|
0.221
|
3×2500
|
|
0.232
|
4、60kV級全絕緣變(bian)壓器的電容(pF)
類 型
|
變 壓(ya) 器 容 量 kVA
|
630
|
2000
|
3150
|
6300
|
8000
|
1600
|
高壓-地(di)
|
2700
|
4100
|
4600
|
5900
|
7000
|
8200
|
低(di)壓-地(di)
|
4200
|
6600
|
7900
|
10000
|
11000
|
15300
|
對于表中沒有的產品,可根據(ju)表中的上、下容量(liang)近似地估算。同容量(liang)的雙繞組(zu)變壓器,其繞組(zu)電(dian)容要比三繞組(zu)產品小(xiao)。
5、110kV級中性點(dian)分級絕緣變壓(ya)器的電容(pF)
類 型
|
變 壓 器(qi) 容 量kVA
|
50000
|
31500
|
20000
|
10000
|
5600
|
高壓-中壓、低壓、地
|
14200
|
11400
|
8700
|
6150
|
4200
|
中壓-高(gao)壓、低(di)壓、地
|
24800
|
11800
|
13200
|
9600
|
-
|
低壓-高(gao)壓、中壓、地(di)
|
19300
|
19300
|
12000
|
9400
|
6800
|
6、220kV級中性點非全(quan)級絕緣(yuan)部(bu)分變壓器的電容(pF)
試 品 型 號
|
SEPSL-63000
|
SSPSL-120000
|
SSPSL-240000
|
類 型
|
高(gao)壓(ya)-中(zhong)壓(ya)、低壓(ya)及地(di)
|
12100
|
13500
|
17050
|
中壓-高壓、低壓及地
|
18500
|
19700
|
23260
|
低(di)壓-高壓、中壓及地
|
18200
|
23600
|
29940
|
試 品 型(xing) 號(hao)
|
SFPL-240000
|
SFP-360000
|
SFPSZL-120000
|
類 型
|
高(gao)壓(ya)-中(zhong)壓(ya)、低壓(ya)及(ji)地
|
32230
|
33910
|
38020
|
中(zhong)壓(ya)-高壓(ya)、低(di)壓(ya)及地
|
-
|
-
|
23260
|
低(di)壓(ya)-高壓(ya)、中壓(ya)及(ji)地
|
22470
|
23790
|
22160
|
7、油浸式(shi)電(dian)力(li)變壓(ya)器(qi)交流試驗電(dian)壓(ya)
額定電(dian)壓(ya)
(k V)
|
*高(gao)工作
電壓(ya)(k V)
|
線端(duan)交流試驗電壓值(kV)
|
中性(xing)點交流(liu)試驗電(dian)壓值(kV)
|
全部(bu)更換繞(rao)組
|
部分更換繞組或交接
|
全(quan)部更換繞組
|
部(bu)分(fen)更換繞組或交接
|
<1
|
≤1
|
3
|
2.5
|
3
|
2.5
|
3
|
3.5
|
18
|
15
|
18
|
15
|
6
|
6.9
|
25
|
21
|
25
|
21
|
10
|
11.5
|
35
|
30
|
35
|
30
|
15
|
17.5
|
45
|
38
|
45
|
38
|
20
|
23.0
|
55
|
47
|
55
|
47
|
35
|
40.5
|
85
|
72
|
85
|
72
|
110
|
126.0
|
200
|
170(195)
|
95
|
80
|
220
|
252.0
|
360
|
306
|
85
|
72
|
395
|
336
|
(200)
|
(170)
|
500
|
550.0
|
630
|
536
|
85
|
72
|
680
|
578
|
140
|
120
|
8、部分型號發電(dian)機定(ding)子(zi)繞組的單相(xiang)對地電(dian)容(rong)量(liang)
類別
|
發 電(dian) 機
|
型(xing)號
|
生產廠家
|
額(e)定容(rong)量(MW)
|
額定(ding)電(dian)壓(ya)(kV)
|
相電容(rong)(mF)
|
火
力
發
電
機(ji)
|
QFS-125-2
|
上海電機廠(chang)
|
125
|
13.8
|
0.08-0.12
|
QFSN-200-2
|
哈爾濱電機(ji)廠
|
200
|
15.75
|
0.19-0.21
|
QFQS-200-2
|
東(dong)方電(dian)機廠(chang)
|
200
|
15.75
|
0.1928-0.21
|
QFQS-200-2
|
北(bei)京重型電機廠
|
200
|
15.75
|
0.18-0.19
|
QFS-300-2
|
上海電機廠
|
300
|
18.0
|
0.16-0.20
|
QFSN-300-2
|
上海電機廠
|
300
|
18.0
|
0.18-0.20
|
ATB-2
|
美國GE公司
|
352
|
23.0
|
0.268(設計值)
|
TBB-320-2
|
(前蘇(su)聯)
|
320
|
20.0
|
0.31
|
2-105×234
|
美國西屋(wu)公司
|
600
|
20.0
|
0.2(工(gong)廠(chang)試驗值(zhi))
|
50WT23E-138
|
ABB
|
600
|
22.0
|
0.253(設計值)
|
水 發(fa)
力 電
機
|
|
|
72.5 - 85
|
10.5
|
0.694
|
|
|
300
|
15.75
|
1.7-2.5
|
|
|
400
|
18.0
|
2-2.5
|
9、同(tong)步(bu)發電機定(ding)子繞組交流試驗(yan)電壓
1
|
全部更換定子繞組并修(xiu)好后的試(shi)驗電(dian)壓
|
容量kW或kVA
|
小于(yu)10000
|
10000及以上
|
額定電(dian)壓Un (V)
|
36以(yi)上(shang)
|
6000以下
|
6000~18000
|
18000以上(shang)
|
試驗電壓V
|
2Un+1000但*低為1500
|
2.5Un
|
2Un
+3000
|
按專門協議
|
2
|
大修(xiu)前或局部更換(huan)定(ding)子繞組并(bing)修(xiu)好后的試驗電壓(ya)
|
運行20年(nian)及以下者
|
1.5 Un
|
運行(xing)20年(nian)以(yi)上與架空線路直接連接者
|
1.5 Un
|
運行20年(nian)以上不與架空(kong)線路直接連(lian)接者
|
(1.3~1.5)Un
|
十(shi)五、設備(bei)成套性:
變頻電源(yuan) 1臺
勵磁變壓器 1臺(tai)
電(dian)抗器 4臺
電容分(fen)壓器(qi) 1臺
附件及測試線(xian) 1套
支架 15KV 1只(zhi)
均壓罩 200KV 2只
絕緣(yuan)底(di)板(ban) 2塊
一、產品概述(shu)
YDQC系列輕型交(jiao)直(zhi)流高(gao)壓(ya)試驗(yan)(yan)(yan)變(bian)壓(ya)器(qi)(qi)是在同類產(chan)品YDJ(G)型高(gao)壓(ya)試驗(yan)(yan)(yan)變(bian)壓(ya)器(qi)(qi)的基礎上,按(an)試驗(yan)(yan)(yan)變(bian)壓(ya)器(qi)(qi)國家標準ZBK41006—89要求,經改進(jin)后生產(chan)的一種新(xin)型產(chan)品,本系列產(chan)品具有體積小、重量輕、結構緊湊、功能齊全、使用(yong)方便等特點。實用(yong)于電力、工礦、科研(yan)等部門,對各種高(gao)壓(ya)電氣設(she)備、電氣元件、絕(jue)緣材(cai)料進(jin)行工頻耐壓(ya)試驗(yan)(yan)(yan)和直(zhi)流泄漏(lou)試驗(yan)(yan)(yan),是高(gao)壓(ya)試驗(yan)(yan)(yan)中必不可少的儀器(qi)(qi)。
二、產品結構
YDQC系列輕型(xing)高(gao)壓(ya)(ya)試驗變壓(ya)(ya)器(qi)(qi)鐵(tie)芯(xin)(xin)為單框式。線圈采用同芯(xin)(xin)圓筒(tong)多(duo)層塔式結(jie)構,初(chu)級(ji)低(di)壓(ya)(ya)繞組繞在(zai)鐵(tie)芯(xin)(xin)上,次(ci)級(ji)高(gao)壓(ya)(ya)繞組繞在(zai)低(di)壓(ya)(ya)繞組外側,這種同軸布置減少了繞組間的(de)藕合損耗。高(gao)壓(ya)(ya)硅(gui)堆用特殊工(gong)藝封裝在(zai)套管內(nei),產品的(de)外殼(ke)制成與(yu)器(qi)(qi)芯(xin)(xin)配合較(jiao)佳的(de)八角(jiao)形結(jie)構,整體外型(xing)美觀大方(fang)。其(qi)內(nei)外部結(jie)構見圖1。
1-均壓(ya)球(qiu);2-硅堆短路桿;3-高(gao)壓(ya)套(tao)管;4-油(you)閥;5-殼體(ti);6、7-調(diao)整電壓(ya)輸入(ru)a、x端(duan)(duan)子(zi);8、9-儀表(biao)測(ce)量(liang)E、F端(duan)(duan)子(zi);10-高(gao)壓(ya)尾X端(duan)(duan)子(zi);11-變(bian)(bian)壓(ya)器外殼接地端(duan)(duan);12-高(gao)壓(ya)輸出(chu)A端(duan)(duan)子(zi);13-高(gao)壓(ya)整流硅堆;14-內部均壓(ya)環;15-變(bian)(bian)壓(ya)器鐵芯(xin);16-初級低(di)壓(ya)繞組(zu);17-測(ce)量(liang)儀表(biao)繞組(zu);18-二次級高(gao)壓(ya)繞組(zu);19-變(bian)(bian)壓(ya)器油(you)。
三、工作(zuo)原(yuan)理
YDQC系(xi)列輕型高(gao)(gao)壓(ya)(ya)(ya)(ya)試(shi)(shi)(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)器為(wei)單相變(bian)壓(ya)(ya)(ya)(ya)器,聯結組標號(hao)II。單臺(tai)(tai)高(gao)(gao)壓(ya)(ya)(ya)(ya)試(shi)(shi)(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)器的工作(zuo)過程(cheng),用交流220V(10KVA以(yi)上為(wei)380V)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)接(jie)入電(dian)(dian)(dian)源控制箱(臺(tai)(tai)),經電(dian)(dian)(dian)源控制箱(臺(tai)(tai))內自藕(ou)調壓(ya)(ya)(ya)(ya)器(50KVA以(yi)上調壓(ya)(ya)(ya)(ya)器外附)調節0~200V(10KVA以(yi)上0~400V)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)至試(shi)(shi)(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)器的初級繞組,根據電(dian)(dian)(dian)磁感應原(yuan)理(li),在試(shi)(shi)(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)器高(gao)(gao)壓(ya)(ya)(ya)(ya)繞組可獲(huo)得試(shi)(shi)(shi)驗(yan)(yan)所(suo)需的高(gao)(gao)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)。其工作(zuo)原(yuan)理(li)圖見圖2所(suo)示。
1、單臺YDQC高壓(ya)試驗變壓(ya)器工作(zuo)原理示意圖(tu)
在試驗變壓器中:a、x為低(di)壓輸入端;A、X 為高壓輸出端;E、F為儀表測量端。
2、單臺交直流兩用型高壓試驗變壓器工作原理見圖3。圖中所示:高壓套管內裝有高壓硅堆,串接在高壓回路中作高壓整流,以獲得直流高電壓。當用一短路桿將高壓硅堆短接時,可獲得交流高電壓,其狀態為交流輸出;反之在抽出短路桿時,其狀態為直流輸出。
3、三臺高壓試驗變壓器串激獲得更高電壓原理見圖4,串激高壓試驗變壓器有很大的優越性,因為整個試驗裝置由多個單臺串激式試驗變壓器組成,單臺試驗變壓器有著體積小、重量輕、便于運輸的特點,它既可以串接成高出幾倍的單臺試驗變壓器輸出電壓組合使用,又可以分開單獨使用。整套試驗裝置投資小、經濟實惠。圖3所示:在三臺串激式試驗變壓器串激使用中,單臺試驗變壓器B1、B2、B3的輸出電壓都是U,**、二級的試驗變壓器內部都有一個激磁繞組,分別為A1、C1 和A2、C2。當控制電壓加在第**試驗變壓器B1的初級繞組a1、x1上,激磁繞組A1、C1給予試驗變壓器B2初級繞組供電,**級試驗變壓器B2的激磁繞組A2、C2給試驗變壓器B3的初級繞組供電。由于第**試驗變壓器B1的高壓尾及殼體接地,**、三級的試驗變壓器B2和B3對地有絕緣支架的隔離,這樣試驗變壓器B1、B2、B3對地輸出電壓分別為1U、2U、3U。
B1、B2、B3- 串激式高(gao)壓變壓器;1U、2U、3U-各級對(dui)地電(dian)壓;
PV- 高壓示值表(KV); ZJ1、ZJ2-絕(jue)緣支(zhi)架(jia)。
四、使用方法及注意事項
1、YDQC高壓(ya)試驗變壓(ya)器(qi)做(zuo)工(gong)頻(pin)耐壓(ya)試驗使(shi)用接(jie)線方法見圖(tu)5。做(zuo)工(gong)頻(pin)耐壓(ya)試驗前,先根據試驗變壓(ya)器(qi)的額定容量選擇好(hao)限流電(dian)阻,(水電(dian)阻)的阻值,再根據被試品(pin)需加的高壓(ya)電(dian)壓(ya)值調整好(hao)放(fang)電(dian)球隙(xi)的球間距(ju),為了提(ti)高對被試品(pin)施加電(dian)壓(ya)的測量精度,應在高壓(ya)側接(jie)入FRC阻容分壓(ya)器(qi)來測量電(dian)壓(ya)。
R1、R2- 限(xian)流電阻; Qx- 放(fang)電球隙; Zx- 被(bei)試品;
FRC- 阻容分壓器; V- 分壓器高壓表。
按照圖4、結合圖2所進行的工頻耐壓試驗接好工作線路,試驗變壓器的高壓繞阻的X端(高壓尾)、儀表測量繞組的F端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
用三臺試驗變壓器串激做工頻耐壓試驗時、**、三級試驗變壓器的初級繞組X端,儀表測量繞組的F端,以及高壓繞組的X端(高壓尾)均接本級試驗變壓器的外殼,**、三級試驗變壓器的主體必須放置在絕緣支架上。除第**以外、**、三級試驗變壓器的主體不要接地線。其接線方式見圖3所示。
接電源前,電源控制箱(臺)的調壓器必須調到零位。接通電源后,綠色指示燈亮,按一下啟動按鈕,紅色指示燈亮,表示試驗變壓器已接通控制電源,開始升壓。
從零位開始按順時針方向勻速旋轉調壓器手輪升壓。(升壓方式有:快速升壓法,即20S逐級升壓法,慢速升壓法,即60S逐級升壓法,極慢速升壓法供選用)電壓從零開始按選定的升壓速度升到您所需額定試驗電壓的75%后,再以每秒2%額定試驗電壓的速度升到您所需試驗電壓,并密切注意測量儀表的指示以及被試品的情況,被試品施加電壓的時間到后。應在數秒內勻速將調壓器返回,高壓降至1/3試驗電壓以下,按一下停止按鈕,高壓、低壓輸出停止,然后切斷電源線,試驗完畢。
工頻耐壓試驗操作過程注意事項
1、試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
2、被試品主要部位應**干凈,保持**干燥,以免損壞被試品和帶來試驗數值的誤差。
3、對大型設備的試驗,一般都應先進行試驗變壓器的空升試驗,即不接試品時升壓至試驗電壓,以便校對好儀表的指示精度,調整好放電球隙的球間距。
4、做耐壓試驗時升壓速度不能過快,并防止突然加壓,例如調壓器不在零位的突然合閘,也不能突然斷電,一般應在調壓器降至零位時分閘。
5、在升壓或耐壓試驗過程中,如發現下列不正常情況,1 電壓、電流表指針擺動很大,2 被試品發出不正常響聲,3 發現絕緣有燒焦或冒煙現象,應立即降壓,切斷電源,停止試驗并查明原因。
6、使用本產品做高壓試驗時,除熟悉本說明書外,還必須嚴格執行國家有關標準和操作規程。
2、YDQ交(jiao)直流(liu)兩(liang)用(yong)高(gao)壓(ya)試驗(yan)(yan)變壓(ya)器做直流(liu)耐壓(ya)和(he)泄漏(lou)試驗(yan)(yan)使用(yong)接線方法見圖5。由于是交(jiao)直流(liu)兩(liang)用(yong)高(gao)壓(ya)試驗(yan)(yan)變壓(ya)器,應(ying)(ying)把高(gao)壓(ya)硅堆短(duan)路(lu)桿從套管中抽出,使試驗(yan)(yan)變壓(ya)器為直流(liu)輸出狀態(tai)。做直流(liu)泄漏(lou)試驗(yan)(yan)前,先根據(ju)泄漏(lou)試驗(yan)(yan)中輸出端斷路(lu)電(dian)(dian)(dian)流(liu)不超過高(gao)壓(ya)硅堆的(de)(de)*大整流(liu)為宜(yi),選(xuan)擇好(hao)限流(liu)電(dian)(dian)(dian)阻(zu)(水電(dian)(dian)(dian)阻(zu))的(de)(de)阻(zu)值(zhi),再(zai)根據(ju)被試品對(dui)直流(liu)高(gao)壓(ya)波形的(de)(de)要求選(xuan)擇好(hao)高(gao)壓(ya)濾波電(dian)(dian)(dian)容(rong)的(de)(de)電(dian)(dian)(dian)容(rong)值(zhi)。為了提高(gao)對(dui)被試品施加電(dian)(dian)(dian)壓(ya)的(de)(de)測量精(jing)度,應(ying)(ying)在高(gao)壓(ya)側(ce)接入(ru)FRC阻(zu)容(rong)分壓(ya)器來測量電(dian)(dian)(dian)壓(ya)。
R- 限流電阻; C- 高壓濾波電容; Zx- 被試品(pin); G- 硅堆(dui)短(duan)路桿(gan);
FRC- 阻容分壓器;V- 分壓器高壓表;uA- 微安表;D- 高壓整流硅堆。
按照圖5、結合圖3所進行的直流泄漏試驗接好工作線路。試驗變壓器的高壓繞組的X端(高壓尾)、儀表測量繞組的F 端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
接電(dian)源前、電(dian)源控制箱(臺)的調壓(ya)器必須調到零位(wei)。接通(tong)(tong)電(dian)源后(hou),綠色指示燈亮(liang),按一下啟動按鈕,紅(hong)色指示燈亮(liang),表示試(shi)驗變壓(ya)器已接通(tong)(tong)控制電(dian)源,開始升(sheng)壓(ya)。
從(cong)零位(wei)開始(shi)按順時針方向勻速(su)旋(xuan)轉調壓(ya)(ya)(ya)(ya)器手輪升(sheng)(sheng)壓(ya)(ya)(ya)(ya)。(升(sheng)(sheng)壓(ya)(ya)(ya)(ya)方式有:快速(su)升(sheng)(sheng)壓(ya)(ya)(ya)(ya)法(fa)即20S逐級升(sheng)(sheng)壓(ya)(ya)(ya)(ya)法(fa);慢(man)速(su)升(sheng)(sheng)壓(ya)(ya)(ya)(ya)法(fa),即60S逐級升(sheng)(sheng)壓(ya)(ya)(ya)(ya)法(fa);級慢(man)速(su)升(sheng)(sheng)壓(ya)(ya)(ya)(ya)法(fa)供選(xuan)用)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)從(cong)零開始(shi)按選(xuan)定的(de)升(sheng)(sheng)壓(ya)(ya)(ya)(ya)速(su)度升(sheng)(sheng)到您所(suo)需額定試驗(yan)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)或額定直(zhi)流電(dian)(dian)(dian)流下(xia)的(de)參考電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)。試驗(yan)中應嚴密注意直(zhi)流高壓(ya)(ya)(ya)(ya)表、泄漏電(dian)(dian)(dian)流表指示以及被試品的(de)情況。試驗(yan)完畢后,應訊速(su)均勻將高壓(ya)(ya)(ya)(ya)降至零位(wei),按一下(xia)停(ting)止按鈕(niu),高壓(ya)(ya)(ya)(ya)、低(di)壓(ya)(ya)(ya)(ya)輸出停(ting)止,然后切斷(duan)電(dian)(dian)(dian)源。此時應用直(zhi)流高壓(ya)(ya)(ya)(ya)放(fang)**給被試品及試驗(yan)裝置本(ben)身(shen)充分放(fang)電(dian)(dian)(dian)。
直(zhi)流泄漏試(shi)驗(yan)操作過程(cheng)注(zhu)意(yi)事項
(1)試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
(2)被試品做試驗前,應拆除所有對外連線,并充分放電,主要部位應**干凈,保持**干燥,以免損壞被試品及帶來試驗數值的誤差。
(3)對于大容量試品(電容器、超長電纜等)試驗時應緩慢升壓,防止被試品的充電電流過大而燒壞微安表,必要時應分級加壓分別讀取各電壓下微安表的穩定讀數。
(4)試驗過程中,應嚴密監視被試品、微安表及試驗裝置等,一旦發生閃爍、擊穿等現象應立即降壓,切斷電源,并查明原因。
五、配套選(xuan)購產品
下列產品僅供選擇,購買時需另行計價。
1.KZX系列電源控制箱 容量:1KVA-5KVA、輸入電壓:220V
2.KZT系列電源控制臺 容量:10KVA~300KVA輸入電壓:220V或380V
3.數字微安表:SWB-II
4.高壓濾波電容: 0.01MF、40 ~ 100KV
5.高壓直流放**: FBR— 70、140、210KV
6.放電球隙: Q—50、100、150、200、250、500
7.標準試油杯: 400ml
8.折疊式手推車: 150、300型
9.絕緣支架: 50、100、200、300、400KV
10.阻容分壓器: FRC —50、100、150、200KV
11.高壓硅堆: 2DL—150、300、450KV
12.水 電 阻: 50、100
六(liu)、主要試(shi)驗設(she)備的選擇(ze)
1、試驗變壓器
其高壓側額定電壓應不小于被試品的*高試驗電壓,額定電流不小于被試品的*大電容電流。被試品的電容電流和試驗變壓器所需容量計算式為:
被試(shi)品電(dian)(dian)容量(liang)Cx可由交流電(dian)(dian)橋(qiao)測(ce)出。常(chang)用(yong)的被試(shi)品電(dian)(dian)容量(liang)按表1選(xuan)取。
幾種常用被試品的電容量(pF) 表1
2、調壓設備
(1)自藕調壓器。其調壓范圍廣、功率損耗小、波形畸變小、選擇這種調壓方式為*好。自藕調壓器的容量按0.75 ~ 1倍的試驗變壓器的容量選擇,適用于容量為100KVA以下的試驗變壓器的調壓。
(2)感應調壓器。其調壓范圍大,波形畸形小、但結構復雜、價格較貴,當試驗變壓器的容量較大時(如100KVA以上)使用。
3、限流電阻
限流電阻的作用是,當被試品擊穿時,限制斷路電流,從而保護試驗變壓器,防止故障的擴大。其數值以*高試驗電壓為準,按0.5 ~ 1 Ω / V(有效值)選擇,限流電阻可用水電阻。注意水不能充滿玻璃管,應留有余地,以防爆裂。
4、放電球隙
放電球隙的布置方式有垂直和水平兩種,球隙間距S和球的直徑D的關系應保護在0.05D ≤S ≤0.5D范圍內,球隙上的水電阻阻值一般按0.1 ~ 1Ω/V選取,設置放電球隙的目的是為了對重要的被試品起保護作用,可以將由于誤操作或被試品擊穿引起的過電壓限制在允許的范圍內。
七(qi)、試驗變(bian)壓器技術指示
型號
|
容量
|
高壓(ya)電壓(ya)
|
高壓電流
|
低壓輸(shu)入
|
變比(bi)
|
溫(wen)升℃
|
(KVA)
|
(KV)
|
(mA)
|
電壓(V)
|
電流(A)
|
高/儀(yi)
|
30分鐘
|
YDQC-1.5/50
|
1.5
|
50
|
30
|
200
|
7.5
|
500
|
10
|
YDQC-3/50
|
3
|
50
|
60
|
200
|
15
|
500
|
10
|
YDQC-5/50
|
5
|
50
|
100
|
200
|
25
|
500
|
10
|
YDQC-10/50
|
10
|
50
|
200
|
200
|
50
|
500
|
10
|
YDQC-15/50
|
15
|
50
|
300
|
200
|
75
|
500
|
10
|
YDQC-20/50
|
20
|
50
|
400
|
380
|
53
|
500
|
10
|
YDQC-30/50
|
30
|
50
|
600
|
380
|
79
|
500
|
10
|
YDQC-50/50
|
50
|
50
|
1000
|
380
|
12
|
500
|
10
|
YDQC-5/100
|
5
|
100
|
50
|
200
|
25
|
1000
|
10
|
YDQC-10/100
|
10
|
100
|
100
|
200
|
50
|
1000
|
10
|
YDQC-20/100
|
20
|
100
|
200
|
400
|
50
|
1000
|
10
|
YDQC-30/100
|
30
|
100
|
300
|
400
|
75
|
1000
|
10
|
YDQC-50/100
|
50
|
100
|
500
|
400
|
125
|
1000
|
10
|
YDQC-20/150
|
20
|
150
|
133
|
400
|
50
|
1500
|
10
|
YDQC-30/150
|
30
|
150
|
200
|
400
|
75
|
1500
|
10
|
YDQC-50/150
|
50
|
150
|
333
|
400
|
125
|
1500
|
10
|
YDQC-100/150
|
100
|
150
|
667
|
400
|
250
|
1500
|
10
|
YDQC-50/200
|
50
|
200
|
250
|
400
|
125
|
2000
|
10
|
YDQC-100/200
|
100
|
200
|
500
|
400
|
250
|
2000
|
10
|
YDQC-150/200
|
150
|
200
|
750
|
400
|
375
|
2000
|
10
|
YDQC-200/200
|
200
|
200
|
1000
|
400
|
500
|
2000
|
10
|
YDQC-300/200
|
300
|
200
|
1500
|
400
|
600
|
2000
|
10
|
YDQC-50/300
|
50
|
300
|
170
|
400
|
125
|
3000
|
10
|
YDQC-100/300
|
100
|
300
|
333
|
400
|
250
|
3000
|
10
|
YDQC-150/300
|
150
|
300
|
500
|
400
|
375
|
3000
|
10
|
YDQC-200/300
|
200
|
300
|
667
|
400
|
500
|
3000
|
10
|
YDQC-300/300
|
300
|
300
|
3000
|
500
|
600
|
3000
|
10
|
1、使用環境條件
環境溫度不高于+40℃、不低于—20℃;空氣相對濕度不大于90%;海拔高度不超過2000米;
2、工作電壓
電源控制箱(臺)輸入電壓為工頻220V或380V、相對誤差不超過±10%;(具體使用電壓根據用戶所定試驗變壓器規格選取)
八、隨貨文件
YDQC 系列試驗變壓器產品說明書 1份
產品出廠試驗報告 1份
產品合格證 1份
裝箱單 1份
一、概述
YDQ系列高(gao)(gao)壓(ya)(ya)(ya)試驗(yan)變壓(ya)(ya)(ya)器是(shi)根據《試驗(yan)變壓(ya)(ya)(ya)器》標準,在油(you)浸(jin)式試驗(yan)變壓(ya)(ya)(ya)器的(de)(de)(de)基礎上而設計生產(chan)的(de)(de)(de)。SF6氣(qi)體(ti)具有良(liang)好的(de)(de)(de)電(dian)氣(qi)絕(jue)緣性(xing)能及(ji)優異的(de)(de)(de)滅弧性(xing)能,其耐(nai)壓(ya)(ya)(ya)強度(du)為同一壓(ya)(ya)(ya)力下氮氣(qi)的(de)(de)(de)2.5倍,擊(ji)穿電(dian)壓(ya)(ya)(ya)的(de)(de)(de)空氣(qi)的(de)(de)(de)2.5倍。在0.25MPa下與油(you)的(de)(de)(de)擊(ji)穿電(dian)壓(ya)(ya)(ya)相(xiang)等(deng),在0.45MPa壓(ya)(ya)(ya)力下是(shi)油(you)的(de)(de)(de)擊(ji)穿電(dian)壓(ya)(ya)(ya)的(de)(de)(de)2倍,是(shi)一種優于油(you)的(de)(de)(de)新一代超高(gao)(gao)壓(ya)(ya)(ya)絕(jue)緣介質材(cai)料。該產(chan)品技術要求完(wan)全符合《ZBK-41006-89》標準,它(ta)是(shi)油(you)浸(jin)式輕型試驗(yan)變壓(ya)(ya)(ya)器的(de)(de)(de)換(huan)代產(chan)品。該產(chan)品具有體(ti)積小(xiao)、重量輕、不受氣(qi)候變化影(ying)響、電(dian)暈小(xiao)、現(xian)場搬運無需靜止可使用,使用壽命長、免維(wei)修等(deng)特點(dian)。適(shi)用于電(dian)力系統、工礦企業、科研部(bu)門等(deng)對各種高(gao)(gao)壓(ya)(ya)(ya)電(dian)氣(qi)設備(bei)、電(dian)氣(qi)元件、絕(jue)緣材(cai)料進行工頻或直(zhi)流高(gao)(gao)壓(ya)(ya)(ya)下的(de)(de)(de)絕(jue)緣強度(du)試驗(yan)。
二、產品結構
YDQ系列(lie)高(gao)壓(ya)(ya)試驗(yan)變(bian)壓(ya)(ya)器采用單框芯(xin)式鐵芯(xin)結(jie)構,初級繞組繞在鐵芯(xin)上(shang),高(gao)壓(ya)(ya)繞組在外,這種(zhong)同軸布(bu)置減少(shao)了漏磁通,因(yin)而增(zeng)大了繞組間的(de)耦(ou)合(he)。產品的(de)外殼為圓柱(zhu)灌式容器結(jie)構,能耐(nai)受(shou)0.8MPa以上(shang)壓(ya)(ya)力(li)。其結(jie)構見圖1:
三、工作原理
YDQ系(xi)列(lie)高(gao)壓(ya)(ya)(ya)試驗(yan)(yan)(yan)變壓(ya)(ya)(ya)器(qi)為單相變壓(ya)(ya)(ya)器(qi),聯結組標(biao)號Ⅰ.Ⅰ. 用(yong)工頻(pin)220V(10kVA以上為380V)電(dian)(dian)源接入 (為本公司生產的(de)試驗(yan)(yan)(yan)變壓(ya)(ya)(ya)器(qi)配套專用(yong)設備,詳細資料請見其具體(ti)使用(yong)說明書)系(xi)列(lie)操作箱(臺),經操作箱內自偶(ou)調壓(ya)(ya)(ya)器(qi)(50kVA以上調壓(ya)(ya)(ya)器(qi)外附(fu))調節至0~200V(或(huo)0~400V)電(dian)(dian)壓(ya)(ya)(ya)輸出至YDQ試驗(yan)(yan)(yan)變壓(ya)(ya)(ya)器(qi)的(de)初級繞(rao)組,根據電(dian)(dian)磁感應原理,在試驗(yan)(yan)(yan)變壓(ya)(ya)(ya)器(qi)高(gao)壓(ya)(ya)(ya)繞(rao)組可(ke)獲得試驗(yan)(yan)(yan)所需(xu)的(de)高(gao)電(dian)(dian)壓(ya)(ya)(ya)。
單臺YDQ系列(lie)交直(zhi)流(liu)(liu)高壓(ya)試驗(yan)變(bian)壓(ya)器的工(gong)作(zuo)原理圖(tu)見圖(tu)3,圖(tu)中高壓(ya)套管中裝(zhuang)有高壓(ya)硅堆(dui),串接在高壓(ya)回(hui)路(lu)(lu)中作(zuo)半(ban)波整(zheng)流(liu)(liu),以獲得直(zhi)流(liu)(liu)高電壓(ya)。當用(yong)一短路(lu)(lu)桿將高壓(ya)硅堆(dui)短接時(shi),可獲得工(gong)頻高電壓(ya),作(zuo)為交流(liu)(liu)輸(shu)(shu)出狀態;取消短路(lu)(lu)桿時(shi),作(zuo)為直(zhi)流(liu)(liu)輸(shu)(shu)出狀態。
圖中:D—短路桿(gan) VD—高壓硅(gui)堆
試驗(yan)變壓器高壓套管中的高壓硅堆未畫出,其(qi)原理與上圖相同。
三(san)臺(tai)試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)串級(ji)(ji)獲得更高電壓(ya)(ya)(ya)(ya)的(de)(de)接線原(yuan)理(li)(li)見(jian)圖(tu)4。串級(ji)(ji)高壓(ya)(ya)(ya)(ya)試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)有很大的(de)(de)優越性,因為(wei)整個(ge)(ge)試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)裝(zhuang)置由幾臺(tai)單(dan)(dan)(dan)臺(tai)試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)組(zu)成(cheng)(cheng),單(dan)(dan)(dan)臺(tai)試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)容量小(xiao)、電壓(ya)(ya)(ya)(ya)低、重(zhong)量輕,便于(yu)運輸(shu)和(he)安(an)裝(zhuang)。它既然(ran)可(ke)串接成(cheng)(cheng)高出(chu)(chu)幾倍的(de)(de)單(dan)(dan)(dan)臺(tai)試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)輸(shu)出(chu)(chu)電壓(ya)(ya)(ya)(ya)組(zu)合(he)使(shi)用(yong),又(you)可(ke)分(fen)(fen)開成(cheng)(cheng)幾套單(dan)(dan)(dan)臺(tai)試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)單(dan)(dan)(dan)獨使(shi)用(yong)。整套裝(zhuang)置投資小(xiao),經濟實惠。圖(tu)5中(zhong)(zhong),在第(di)**和(he)**級(ji)(ji)的(de)(de)每個(ge)(ge)單(dan)(dan)(dan)元試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)中(zhong)(zhong)都(dou)有一個(ge)(ge)勵(li)磁(ci)繞(rao)(rao)組(zu)A1、C1和(he)A2、C2。在三(san)臺(tai)串級(ji)(ji)試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)基本原(yuan)理(li)(li)中(zhong)(zhong),低壓(ya)(ya)(ya)(ya)電源加在試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅰ的(de)(de)初級(ji)(ji)繞(rao)(rao)組(zu)a1x1上(shang),單(dan)(dan)(dan)臺(tai)試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅰ、Ⅱ、Ⅲ的(de)(de)輸(shu)出(chu)(chu)電壓(ya)(ya)(ya)(ya)都(dou)是(shi)V。勵(li)磁(ci)繞(rao)(rao)組(zu)A1、C1給**級(ji)(ji)試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅱ的(de)(de)初級(ji)(ji)繞(rao)(rao)組(zu)供(gong)電;**級(ji)(ji)試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅱ的(de)(de)勵(li)磁(ci)繞(rao)(rao)組(zu)A2、C2給第(di)三(san)級(ji)(ji)試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅲ的(de)(de)初級(ji)(ji)繞(rao)(rao)組(zu)供(gong)電。**級(ji)(ji)試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅱ和(he)第(di)三(san)級(ji)(ji)試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅲ的(de)(de)箱體(ti)(ti)分(fen)(fen)別(bie)(bie)處(chu)在對地為(wei)1V和(he)2V的(de)(de)高電位上(shang),所以箱體(ti)(ti)對地是(shi)絕(jue)緣的(de)(de),試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)Ⅰ的(de)(de)箱體(ti)(ti)是(shi)接地的(de)(de)。這樣第(di)**、**級(ji)(ji)、第(di)三(san)級(ji)(ji)試(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)對地的(de)(de)額定(ding)輸(shu)出(chu)(chu)電壓(ya)(ya)(ya)(ya)分(fen)(fen)別(bie)(bie)為(wei)1V、2V、3V;其額定(ding)容量分(fen)(fen)別(bie)(bie)為(wei)3P、2P、1P。
YDQ系(xi)列高壓(ya)試驗變壓(ya)器做被(bei)試品的工頻耐(nai)壓(ya)試驗使用(yong)接(jie)線原理圖見圖5。
圖中:R1—限流電阻(zu) FRC—阻(zu)容分(fen)壓器 RF—球間隙保護電阻(zu) G—球間隙 CX—被試(shi)品
注:高壓尾(wei)必須(xu)可靠接地
工頻耐壓(ya)試(shi)驗中(zhong)限(xian)流(liu)(liu)電阻R1應(ying)根據試(shi)驗變壓(ya)器的(de)額定容(rong)量來選(xuan)擇。如高壓(ya)側額定輸出電流(liu)(liu)在100~300mA時(shi),可取0.5~1Ω/V(試(shi)驗電壓(ya));高壓(ya)側額定輸出電流(liu)(liu)為(wei)1A以(yi)上時(shi),可取1Ω/V(試(shi)驗電壓(ya))。常(chang)用水(shui)電阻作為(wei)限(xian)流(liu)(liu)電阻,管(guan)子長(chang)度可按(an)150kV/m考慮,管(guan)子粗(cu)細(xi)應(ying)具(ju)有足夠的(de)熱容(rong)量(水(shui)阻液配制方法:用蒸餾水(shui)加入適(shi)量硫酸(suan)銅(tong)配制成各(ge)種不同的(de)阻值(zhi))。
球(qiu)間隙(xi)(xi)(xi)及(ji)保護(hu)電(dian)(dian)(dian)阻(zu):當電(dian)(dian)(dian)壓超過球(qiu)間隙(xi)(xi)(xi)整定值時(一(yi)般取(qu)試(shi)(shi)驗(yan)電(dian)(dian)(dian)壓的110%~120%),球(qiu)間隙(xi)(xi)(xi)放電(dian)(dian)(dian),對(dui)被試(shi)(shi)品起到保護(hu)作用(yong)。球(qiu)間隙(xi)(xi)(xi)保護(hu)電(dian)(dian)(dian)阻(zu)可按1Ω/V(試(shi)(shi)驗(yan)電(dian)(dian)(dian)壓)選取(qu)。
在(zai)工(gong)頻耐(nai)壓(ya)(ya)(ya)(ya)(ya)試(shi)驗(yan)(yan)中,低電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)側(ce)測(ce)量電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(儀表(biao)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya))不是非(fei)常準(zhun)確(que)的,其原因是由于(yu)(yu)(yu)試(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)存(cun)在(zai)著(zhu)漏(lou)抗,在(zai)這個漏(lou)抗上必(bi)(bi)然(ran)存(cun)在(zai)著(zhu)壓(ya)(ya)(ya)(ya)(ya)降或(huo)容(rong)(rong)升,使試(shi)品上的電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)低于(yu)(yu)(yu)或(huo)高于(yu)(yu)(yu)低壓(ya)(ya)(ya)(ya)(ya)側(ce)測(ce)量電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)表(biao)上反(fan)映出來的電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)。工(gong)頻耐(nai)壓(ya)(ya)(ya)(ya)(ya)試(shi)驗(yan)(yan)時,被(bei)試(shi)品上的電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)高于(yu)(yu)(yu)試(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)的輸(shu)出電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya),也就是所謂容(rong)(rong)升現象(xiang)。感應耐(nai)壓(ya)(ya)(ya)(ya)(ya)試(shi)驗(yan)(yan)時,試(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)的漏(lou)抗必(bi)(bi)然(ran)存(cun)在(zai)著(zhu)壓(ya)(ya)(ya)(ya)(ya)降。為(wei)了準(zhun)確(que)測(ce)量被(bei)試(shi)品上所施加(jia)的電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya),因此常在(zai)高壓(ya)(ya)(ya)(ya)(ya)側(ce)接入FRC阻容(rong)(rong)分壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)來測(ce)量電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(見圖5)。
工頻耐(nai)壓試驗操作注意事項
1)試驗(yan)人(ren)員應做好分工,明確相互間聯(lian)系方(fang)法。并有專門(men)人(ren)監(jian)護現場**及觀察試品狀態。
2)被試品應先清(qing)掃(sao)干(gan)(gan)凈,并**干(gan)(gan)燥,以(yi)免損壞被試品和(he)試驗(yan)帶(dai)來的誤差(cha)。
3)對(dui)于大型試驗(yan),一般都(dou)應先(xian)進(jin)行空升試驗(yan)。即不(bu)接試品時升壓至試驗(yan)電壓,校(xiao)對(dui)各種表計,調整(zheng)球間隙(xi)。
4)升(sheng)壓(ya)(ya)(ya)速度不(bu)能太(tai)快,并必須防止突然加壓(ya)(ya)(ya)。例如調(diao)(diao)壓(ya)(ya)(ya)器不(bu)在(zai)零位時突然合閘。也不(bu)能突然切斷電源,一般(ban)應在(zai)調(diao)(diao)壓(ya)(ya)(ya)器降至零位時拉(la)閘。
5)當電(dian)(dian)(dian)壓(ya)升至試驗電(dian)(dian)(dian)壓(ya)時,開始計時,到(dao)(dao)1min后,迅速降壓(ya)到(dao)(dao)1/3試驗電(dian)(dian)(dian)壓(ya)以(yi)下時,才能拉開電(dian)(dian)(dian)源(yuan)。
6)在升壓或耐壓試驗過程中,如發現(xian)(xian)下列(lie)不正(zheng)常情況時,應立即降壓,切(qie)斷(duan)電源。停止試驗并查明原因:①電壓表指(zhi)針擺動(dong)很大;②發現(xian)(xian)絕(jue)緣燒焦或冒煙;③被(bei)試品內有不正(zheng)常的聲音。
7)耐壓試驗前后應測量絕緣(yuan)電阻,檢(jian)查絕緣(yuan)情況(kuang)。
試驗(yan)(yan)變壓器在(zai)做(zuo)被試品的直流耐壓或泄露試驗(yan)(yan)時接線原(yuan)理圖(tu)如(ru)圖(tu)6。
注(zhu):此試驗應先(xian)抽出短路桿“D”,圖6中所示。
圖中:VD—高壓(ya)(ya)硅堆 R1—限流電阻 C1—高壓(ya)(ya)濾波電容(rong)(rong) FRC—阻容(rong)(rong)分壓(ya)(ya)器 CX—被試品(pin) μA—帶保護微安表
泄露試(shi)(shi)驗中限流電(dian)(dian)阻(zu)R1選擇在額定輸出電(dian)(dian)壓時(shi),輸出端短(duan)路電(dian)(dian)流不超(chao)過高(gao)壓硅堆的(de)*大(da)整(zheng)流。如電(dian)(dian)壓硅堆的(de)*大(da)整(zheng)流電(dian)(dian)流為100mA時(shi)用于60kV的(de)試(shi)(shi)驗裝置中,限流電(dian)(dian)阻(zu)按(an)R1=60/0.1=600kΩ選擇。限流電(dian)(dian)阻(zu)還應具有足夠的(de)容量(liang)和(he)沿(yan)面放電(dian)(dian)距離。
高壓(ya)濾波(bo)電容(rong)C1一般選擇(ze)在0.01~0.1μF,當(dang)被(bei)試品的電容(rong)量很大時,C1可省略不用。
泄(xie)露(lu)試驗的(de)操作(zuo)及注(zhu)意事項
1)試(shi)驗(yan)前應先檢查被試(shi)品是否停(ting)電(dian)(dian),接地放電(dian)(dian),一切對外連線是否擦干(gan)凈。要嚴(yan)防將試(shi)驗(yan)電(dian)(dian)壓加到有(you)人工作的部位上去。
2)接(jie)好試驗裝置的接(jie)線(xian)后,應(ying)復查無誤后才可(ke)加壓(ya)。應(ying)特別(bie)注意檢查高(gao)壓(ya)設備及引線(xian)與地、與操作人(ren)員(yuan)的**距離,被試品的外殼是否可(ke)靠接(jie)地,要按**規程中所規定的內容進行試驗。
3)對于大(da)電容量(liang)設(she)備(bei)應緩慢(man)升壓,防止被試品的(de)充電電流燒壞微安表(biao)。必要時應分級加壓,分別讀取各級電壓下(xia)微安表(biao)的(de)穩(wen)定讀數。
4)試驗(yan)過程中(zhong),應密切(qie)監視(shi)被試品(pin)、試驗(yan)裝置、微(wei)安表,一旦發生擊(ji)穿(chuan)、閃爍等異常現(xian)象應立即降(jiang)壓(ya),切(qie)斷電(dian)源,并(bing)查明原因,詳(xiang)細記(ji)錄。
5)試驗(yan)完畢,降(jiang)壓,切斷(duan)電源后應(ying)將被試品及試驗(yan)裝置本身充分放(fang)電。
四、注(zhu)意事(shi)項
1、按(an)照您所進(jin)行的試(shi)(shi)驗(yan)接好(hao)工作線路。試(shi)(shi)驗(yan)變壓器的外殼(ke)以及操作系統的外殼(ke)必(bi)須可(ke)靠接地(di)。試(shi)(shi)驗(yan)變壓器高壓繞組(zu)的X端(高壓尾)以及測量繞組(zu)的F端必(bi)須可(ke)靠接地(di)。
2、做(zuo)串級(ji)試(shi)(shi)驗時,**級(ji)、第三級(ji)試(shi)(shi)驗變壓(ya)器的(de)(de)低(di)壓(ya)繞組(zu)(zu)的(de)(de)X端(duan),測量繞組(zu)(zu)的(de)(de)F端(duan)以及(ji)高壓(ya)繞組(zu)(zu)的(de)(de)X端(duan)(高壓(ya)尾)均接本級(ji)試(shi)(shi)驗變壓(ya)器的(de)(de)外殼。**級(ji)、第三級(ji)試(shi)(shi)驗變壓(ya)器的(de)(de)外殼必須通過絕緣支架(jia)接地。
3、接(jie)通(tong)電(dian)源前,操作(zuo)系統的調壓(ya)(ya)器必須(xu)調到零位后方可接(jie)通(tong)電(dian)源,合閘,開(kai)始升壓(ya)(ya)。
4、從零(ling)開始均(jun)勻旋轉調壓(ya)(ya)器手輪升壓(ya)(ya)。升壓(ya)(ya)方法(fa)有(you):快速(su)升壓(ya)(ya)法(fa),即20s逐(zhu)級升壓(ya)(ya)法(fa);慢速(su)升壓(ya)(ya)法(fa),即60s逐(zhu)級升壓(ya)(ya)法(fa);極(ji)慢速(su)升壓(ya)(ya)法(fa)供(gong)選用。電(dian)(dian)壓(ya)(ya)從零(ling)開始按一定的(de)升壓(ya)(ya)方式和速(su)度上(shang)升到您所需的(de)額(e)定試(shi)驗電(dian)(dian)壓(ya)(ya)的(de)75%后,在以每(mei)秒2%額(e)定試(shi)驗電(dian)(dian)壓(ya)(ya)的(de)速(su)度升到您所需的(de)額(e)定電(dian)(dian)壓(ya)(ya),并密(mi)切(qie)(qie)注意(yi)測量儀(yi)表的(de)指(zhi)(zhi)示(shi)以及被試(shi)品(pin)(pin)的(de)情(qing)況。升壓(ya)(ya)過(guo)程中或(huo)試(shi)驗過(guo)程中如(ru)發現測量儀(yi)表的(de)指(zhi)(zhi)示(shi)及被試(shi)品(pin)(pin)情(qing)況異常,應立即降壓(ya)(ya),切(qie)(qie)斷(duan)電(dian)(dian)源,查明情(qing)況。
5、試驗完畢后(hou),應在數秒內勻速的將調壓器返回至零位,然后(hou)切斷電(dian)源。
6、本產(chan)品(pin)不得(de)超過額定參數使(shi)用。除試驗(yan)必須外,決不允許全(quan)電(dian)壓通電(dian)或斷電(dian)。
7、 再升壓或(huo)耐(nai)壓試驗過(guo)程中(zhong),如發(fa)現以下(xia)不正(zheng)常情況(kuang)時,應立即降壓,切斷電源(yuan),停(ting)止試驗并查明原因。
⑴電壓表指針擺動(或數字跳(tiao)動)很大
⑵電流表直線上升
被試品內有不正常的聲音
8、圖1中(zhong)第9項系壓力(li)閥(fa)及壓力(li)表,為長期(qi)關(guan)閉狀(zhuang)態。每(mei)6個(ge)月(yue)開(kai)閥(fa)一次,以(yi)檢(jian)查SF6壓力(li),應不小于0.2MPa(檢(jian)查壓力(li)后立即關(guan)閉閥(fa)門),低(di)于0.2MPa時應加(jia)SF6氣(qi)體,以(yi)增加(jia)氣(qi)絕緣。
9、耐壓實(shi)驗(yan)前后應測量被試設(she)備的絕緣電阻,檢查絕緣情況。
10、當(dang)試驗變壓器(qi)長期不使用時,應放置于通風(feng)、干燥、無(wu)陽光直射的地方。
11、該產品不允許(xu)在高于45℃的溫度下長期存放、使用、放氣。
12、運(yun)輸搬運(yun)途中(zhong)不得(de)重力沖擊。
13、產(chan)品緊固件及壓力(li)閥、壓力(li)表不得擅自松動。
14、使用本產品做高(gao)壓(ya)試(shi)驗時,出熟悉(xi)本說明書(shu)外,還必須嚴格執行國家有關(guan)標準和(he)操(cao)作規程。可參照GB311-83《高(gao)壓(ya)輸變設備的絕緣配合,高(gao)壓(ya)試(shi)驗技術》;《電(dian)氣設備預防性試(shi)驗規程》等。
五、試(shi)驗變壓器的(de)容量選擇
標稱(cheng)試(shi)驗變壓器容(rong)量Pn的(de)確定公式:Pn=kVn 2ωCt×10-9
式中:
Pn——標稱試驗變壓器(qi)容量(kVA)
Vn——試驗(yan)變壓(ya)器的額(e)定輸(shu)出高壓(ya)的有(you)效值(zhi)(kV)
k ——**系數。k≥1,標稱電壓Vn≥1MV時(shi),k=2;標稱電壓較低時(shi),k值可取(qu)高一些。
Ct——被試品的(de)電容量(liang)(pF)
ω——角(jiao)頻率,ω=2πf,f——試驗電(dian)源的頻率
被試設備的(de)電(dian)容量Ct可由交流電(dian)橋測出。Ct的(de)變(bian)化很大,
可由設(she)備的類型而(er)定(ding)。
典型數據如(ru)下:
簡單的(de)棒式或(huo)懸式絕緣子 幾十(shi)微法
簡單的分(fen)級套管 100~1000pF
電壓(ya)互感器 200 ~ 500pF
電力變壓器 < 1000kVA~1000pF
> 1000kVA 1000~10000pF
高壓(ya)電(dian)力電(dian)纜和油浸紙(zhi)絕緣 250~300pF/m
氣體(ti)絕緣 ~60pF/m
封閉變電站,SF6氣體絕緣 100~10000Pf;
對于(yu)不同的(de)(de)試驗電壓Vn,選(xuan)擇不同的(de)(de)(適(shi)當(dang)的(de)(de))**系數k。
以下(xia)列出不(bu)同的Vn所(suo)選用的k值供參(can)考。
Vn =50~100kV k = 4
Vn =150~300kV k = 3
Vn > 300kV k = 2
一、概述
工頻耐壓(ya)試驗是(shi)(shi)鑒定電力設備絕緣強度的(de)(de)(de)*嚴格、*有效和*直接的(de)(de)(de)方法。它能(neng)(neng)檢查出(chu)那些危險(xian)性(xing)較大的(de)(de)(de)集中缺(que)陷,對判斷電力設備能(neng)(neng)否繼續參加(jia)運行(xing)具有決(jue)定性(xing)作用(yong),是(shi)(shi)保證(zheng)設備絕緣水平、避免發生(sheng)絕緣事故的(de)(de)(de)重要手段。
本裝置是根據(ju)國家*新電(dian)力(li)行(xing)業標準而設(she)計的(de)、性能先進的(de)耐壓試(shi)(shi)驗設(she)備,用于對各種電(dian)器產品、電(dian)氣元件、絕(jue)緣材(cai)料(liao)等進行(xing)規定電(dian)壓下的(de)絕(jue)緣強度試(shi)(shi)驗,以(yi)考核產品的(de)絕(jue)緣水平,發現被(bei)試(shi)(shi)品的(de)絕(jue)緣缺陷,衡(heng)量過(guo)電(dian)壓的(de)能力(li)。
二、產品特(te)點
監(jian)視(shi)功能:高壓電壓 低壓電流 零位指(zhi)示 電源指(zhi)示 工作指(zhi)示 計時指(zhi)示
保(bao)護功能:過(guo)流保(bao)護、零位啟(qi)動保(bao)護、聲光語言(yan)報警提醒
采用(yong)新(xin)型時(shi)間繼電器,計時(shi)范圍更廣(1S~99H)
采用(yong)新(xin)型(xing)電流繼電器,更(geng)**、更(geng)可靠,確保(bao)人身及設備**。
試驗(yan)變壓(ya)器高壓(ya)線圈為圓筒多層塔式,由上等聚酯(zhi)漆包線及(ji)高耐壓(ya)值絕(jue)緣材料繞制而(er)成。
試驗變壓器(5kVA以上)裝有可移(yi)動的鐵輪。具(ju)有重量輕、體(ti)積小、移(yi)動方便、性能(neng)優(you)越等特(te)點(dian)。
三、設備組成
1、選型配置
標(biao)準(zhun)配置
|
□ 分(fen)體式
|
操作部分:
□箱式(shi)(不(bu)大于5kVA) / □臺式(shi)
容量: kVA(小于200kVA)
輸入(ru):□AC220V / □AC380V
|
試驗(yan)變壓(ya)器:
□交流 / □交直(zhi)流
□油變(bian) / □干(gan)變(bian) / □氣變(bian)
容(rong)量: kVA(小于200kVA)
輸出:AC kV(小于300kVA)
|
□ 一體式(shi)
|
□箱(xiang)式(shi)(不大于20kV) / □臺式(shi)(不大于30kV)
容量(liang): kVA(小于300kVA)
輸入(ru):□AC220V / □AC380V 輸出:AC kV(不大(da)于(yu)30kV)
|
客戶選(xuan)配(pei)
|
□標準高壓分壓器
|
□保護(hu)球隙
|
□直流(liu)微安表
|
□放**
|
□保(bao)護水阻
|
□高(gao)壓(ya)濾波電容
|
其它(ta):
|
2、對應實物
四、技術指標(biao)
1、使用(yong)條件:
(1)工作場(chang)所應(ying)無嚴重影響(xiang)絕緣(yuan)的氣體、蒸汽、化學性塵(chen)埃及其它爆炸性和(he)腐蝕性介(jie)質。
(2)環境溫(wen)度 -20~+50℃
(3)環境濕度 ≤85% RH(無凝結水)
2、控(kong)制(zhi)箱(臺)參(can)數(shu):(常規參(can)數(shu)見下表)
規格
|
容量
|
輸 入 電 源
|
輸 出 電 壓
|
重(zhong)量(liang)(kg)
|
相數
|
(V)
|
(A)
|
(V)
|
(A)
|
2/220
|
2
|
1
|
220
|
10
|
0-250
|
8
|
14
|
3/220
|
3
|
1
|
220
|
15
|
0-250
|
12
|
16
|
5/220
|
5
|
1
|
220
|
25
|
0-250
|
20
|
18
|
10/220
|
10
|
1
|
220
|
50
|
0-250
|
40
|
80
|
15/380
|
15
|
2
|
380
|
37.5
|
0-430
|
34.8
|
90
|
20/380
|
20
|
2
|
380
|
50
|
0-430
|
46.5
|
100
|
25/380
|
25
|
2
|
380
|
62.5
|
0-430
|
58.1
|
120
|
30/380
|
30
|
2
|
380
|
75
|
0-430
|
69.7
|
140
|
50/380
|
50
|
2
|
380
|
125
|
0-430
|
116.2
|
160
|
100/380
|
100
|
2
|
380
|
250
|
0-430
|
232.5
|
250
|
說明:如(ru)有特殊參(can)數要求(qiu),可(ke)按用戶的技(ji)術(shu)參(can)數進行設(she)計制(zhi)作。
3、試驗變壓(ya)器參數:(常規參數見下(xia)表)
規格
|
容量
kVA
|
低壓側(ce)
|
高壓側
|
高壓側(交直(zhi)流變壓器)
|
測量(liang)變比
|
60分鐘(zhong)溫升℃
|
阻抗電壓%
|
空載電(dian)流(liu)
%
|
質量
kg
|
電(dian)壓
V
|
電流
A
|
交(jiao)流(liu)輸出
|
直流輸出
|
電壓kV
|
電流
|
電壓kV
|
電(dian)流
|
1.5/50
|
1.5
|
200
|
7.5
|
50
|
30
|
70
|
21.4
|
500
|
50
|
10
|
<4
|
19.5
|
3/50
|
3
|
200
|
15
|
50
|
60
|
70
|
42.9
|
500
|
50
|
10
|
<4
|
27
|
5/50
|
5
|
200
|
25
|
50
|
100
|
70
|
71.4
|
500
|
50
|
10
|
<4
|
52
|
10/50
|
10
|
200
|
50
|
50
|
200
|
70
|
142.9
|
500
|
50
|
10
|
<4
|
80
|
15/50
|
15
|
400
|
37.5
|
50
|
300
|
70
|
214.3
|
500
|
50
|
8
|
<4
|
120
|
20/50
|
20
|
400
|
50
|
50
|
400
|
70
|
285.7
|
500
|
50
|
8
|
<4
|
140
|
30/50
|
30
|
400
|
75
|
50
|
600
|
70
|
428.6
|
500
|
50
|
8
|
<4
|
155
|
50/50
|
50
|
400
|
125
|
50
|
1000
|
70
|
714.3
|
500
|
50
|
8
|
<4
|
184
|
10/100
|
10
|
200
|
50
|
100
|
100
|
140
|
71.4
|
1000
|
50
|
10
|
<4
|
135
|
15/100
|
15
|
400
|
37.5
|
100
|
150
|
140
|
107.1
|
1000
|
50
|
8
|
<4
|
150
|
20/100
|
20
|
400
|
50
|
100
|
200
|
140
|
142.9
|
1000
|
50
|
8
|
<4
|
215
|
30/100
|
30
|
400
|
75
|
100
|
300
|
140
|
214.3
|
1000
|
50
|
8
|
<4
|
250
|
50/100
|
50
|
400
|
125
|
100
|
500
|
140
|
357.1
|
1000
|
50
|
8
|
<4
|
290
|
10/150
|
10
|
200
|
50
|
100
|
66.7
|
140
|
47.6
|
1500
|
50
|
10
|
<4
|
180
|
15/150
|
15
|
400
|
37.5
|
150
|
100
|
210
|
71.4
|
1500
|
50
|
8
|
<4
|
200
|
20/150
|
30
|
400
|
50
|
150
|
133.3
|
210
|
95.2
|
1500
|
50
|
8
|
<4
|
220
|
30/150
|
30
|
400
|
75
|
150
|
200
|
210
|
142.9
|
1500
|
50
|
8
|
<4
|
280
|
50/150
|
50
|
400
|
125
|
150
|
333.3
|
210
|
238.1
|
1500
|
50
|
8
|
<4
|
340
|
說明(ming):如有(you)特殊參數要求,可按用戶的技術參數進行設計制作(zuo)。
上(shang)表的(de)重量(liang)以油(you)浸(jin)式(shi)試(shi)(shi)驗(yan)變(bian)壓器為例,干式(shi)試(shi)(shi)驗(yan)變(bian)壓器和充氣式(shi)試(shi)(shi)驗(yan)變(bian)壓器稍有不同。
五、接線及(ji)工作原理(li)
1、調壓部分(fen)接線及原理
調壓部(bu)分(fen)由控(kong)(kong)制(zhi)部(bu)分(fen)和試(shi)驗變壓器(qi)組(zu)成(cheng)(cheng)。控(kong)(kong)制(zhi)部(bu)分(fen)是由接觸式調壓器(qi)及其控(kong)(kong)制(zhi)、保護、測(ce)量、信號電(dian)路(lu)組(zu)成(cheng)(cheng)。試(shi)驗變壓器(qi)由低壓繞(rao)組(zu)、高(gao)壓繞(rao)組(zu)、儀表(biao)繞(rao)組(zu)三部(bu)分(fen)組(zu)成(cheng)(cheng)。
試驗變壓器為(wei)(wei)交(jiao)直流(liu)兩用時(shi),試驗變壓器配置(zhi)(zhi)了高壓硅(gui)堆(油(you)變、氣(qi)(qi)變為(wei)(wei)內置(zhi)(zhi),干(gan)變為(wei)(wei)外置(zhi)(zhi)),高壓可輸(shu)出交(jiao)流(liu)和(he)直流(liu)。輸(shu)出交(jiao)流(liu)時(shi),要求接(jie)入(ru)短路桿(gan)(油(you)變、氣(qi)(qi)變)或去(qu)掉外置(zhi)(zhi)硅(gui)堆(干(gan)變);輸(shu)出直流(liu)時(shi),要求擰(ning)出短路桿(gan)(油(you)變、氣(qi)(qi)變)或加(jia)上(shang)外置(zhi)(zhi)硅(gui)堆(干(gan)變)
通過接入工(gong)頻電源,調(diao)節(jie)調(diao)壓器(qi),以獲得所需要的試驗高壓電壓值。其(qi)工(gong)作原理見圖1:
2、試驗部分接線及原理
做耐壓試驗時(shi),控(kong)制部分、變壓器的(de)接(jie)地(di)端及高(gao)壓尾必須可靠(kao)接(jie)地(di)。有條件的(de)情(qing)況下,做工(gong)頻耐壓試驗請加上限流電阻、標(biao)準(zhun)高(gao)壓分壓器、球(qiu)隙(xi)保(bao)護電阻及保(bao)護球(qiu)隙(xi),如圖(tu)3。
做(zuo)直流(liu)(liu)耐壓試(shi)驗請另外加上微安表(biao),微安表(biao)必(bi)須(xu)接在(zai)(zai)硅(gui)堆(dui)(dui)和(he)(he)被試(shi)器之間(jian),油變或氣(qi)變一般(ban)擰在(zai)(zai)高壓頭(tou)上面(mian)(mian)(要(yao)求擰出短路(lu)桿),干(gan)變擰在(zai)(zai)外置(zhi)硅(gui)堆(dui)(dui)上面(mian)(mian);為了(le)更準確顯示高壓直流(liu)(liu)泄漏電流(liu)(liu),請將分壓器的高壓線接在(zai)(zai)微安表(biao)和(he)(he)硅(gui)堆(dui)(dui)之間(jian),(油變、氣(qi)變)如圖4,(干(gan)變)如圖5。
耐壓(ya)試(shi)(shi)驗中限(xian)流(liu)電(dian)(dian)(dian)阻(zu)R1應根據試(shi)(shi)驗變(bian)壓(ya)器的(de)(de)額定(ding)容量(liang)來選擇。如高(gao)(gao)壓(ya)側額定(ding)輸出(chu)電(dian)(dian)(dian)流(liu)在100~300mA時(shi),可取(qu)(qu)0.5~1Ω/V(試(shi)(shi)驗電(dian)(dian)(dian)壓(ya));高(gao)(gao)壓(ya)側額定(ding)輸出(chu)電(dian)(dian)(dian)流(liu)為(wei)(wei)1A以上時(shi),可取(qu)(qu)1Ω/V(試(shi)(shi)驗電(dian)(dian)(dian)壓(ya))。常用水(shui)電(dian)(dian)(dian)阻(zu)作為(wei)(wei)限(xian)流(liu)電(dian)(dian)(dian)阻(zu),管子(zi)長(chang)度可按150kV/m考慮,管子(zi)粗細應具有足夠(gou)的(de)(de)熱(re)容量(liang)(水(shui)阻(zu)液配制方(fang)法(fa):用蒸餾水(shui)加入適量(liang)硫酸銅配制成各種不同的(de)(de)阻(zu)值)。
球(qiu)(qiu)間隙及(ji)保護(hu)電(dian)(dian)阻:當電(dian)(dian)壓(ya)超過球(qiu)(qiu)間隙整定(ding)值時(shi)(一般取(qu)試驗(yan)電(dian)(dian)壓(ya)的(de)110%~120%),球(qiu)(qiu)間隙放電(dian)(dian),對被試品(pin)起(qi)到保護(hu)作用。球(qiu)(qiu)間隙保護(hu)電(dian)(dian)阻可按1Ω/V(試驗(yan)電(dian)(dian)壓(ya))選取(qu)。
在(zai)工頻(pin)(pin)耐(nai)壓(ya)(ya)(ya)試(shi)驗(yan)中,低電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)側測(ce)量(liang)(liang)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)(儀表電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya))不是非常準(zhun)確(que)的(de)(de)(de),其原因是由于(yu)(yu)試(shi)驗(yan)變壓(ya)(ya)(ya)器存在(zai)著漏(lou)抗,在(zai)這個漏(lou)抗上(shang)必然(ran)存在(zai)著壓(ya)(ya)(ya)降或容升,使試(shi)品上(shang)的(de)(de)(de)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)低于(yu)(yu)或高(gao)(gao)于(yu)(yu)低壓(ya)(ya)(ya)側測(ce)量(liang)(liang)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)表上(shang)反映(ying)出(chu)來的(de)(de)(de)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)。工頻(pin)(pin)耐(nai)壓(ya)(ya)(ya)試(shi)驗(yan)時(shi),被(bei)試(shi)品上(shang)的(de)(de)(de)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)高(gao)(gao)于(yu)(yu)試(shi)驗(yan)變壓(ya)(ya)(ya)器的(de)(de)(de)輸出(chu)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya),也就是所(suo)謂容升現象。感應耐(nai)壓(ya)(ya)(ya)試(shi)驗(yan)時(shi),試(shi)驗(yan)變壓(ya)(ya)(ya)器的(de)(de)(de)漏(lou)抗必然(ran)存在(zai)著壓(ya)(ya)(ya)降。為了(le)準(zhun)確(que)測(ce)量(liang)(liang)被(bei)試(shi)品上(shang)所(suo)施加的(de)(de)(de)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya),因此常在(zai)高(gao)(gao)壓(ya)(ya)(ya)側接(jie)入標準(zhun)高(gao)(gao)壓(ya)(ya)(ya)分(fen)壓(ya)(ya)(ya)器來測(ce)量(liang)(liang)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)。
五、面板結(jie)構說(shuo)明
1、操作箱面板
控制箱為(wei)箱式(shi)鋁合(he)金結構,面板采用(yong)拉(la)絲鋁合(he)金工藝,所有電器元(yuan)件(jian)均裝(zhuang)在骨架上,便(bian)于安裝(zhuang)和維修(xiu)。面板元(yuan)件(jian)布(bu)置如(ru)下(xia):
2、操作臺面(mian)板
操(cao)作臺為臺式結構,殼體(ti)為冷(leng)扎鋼板(ban)結構,面(mian)板(ban)采用鋁合(he)金拉(la)絲工藝(yi),面(mian)板(ban)元件布置如下:
六、操作(zuo)指南
本(ben)裝置在操作之前應根據不同被試品的容量、電壓(ya)等級,先(xian)計算(suan)好(hao)*大工(gong)作電流,并調整電流保護器。其試驗(yan)接線應參(can)考本(ben)說明書中圖1、圖2、圖3、圖4、圖5,必須(xu)可靠接地。
1、操作要點(dian)
(1)試(shi)驗前,應了(le)解被試(shi)品的試(shi)驗電壓(ya),同(tong)時(shi)了(le)解被試(shi)品的其(qi)他試(shi)驗項目(mu)及以前的試(shi)驗結果。若被試(shi)品有缺陷(xian)或(huo)異常,應在消除后再進行耐壓(ya)試(shi)驗。
(2)試驗現場應圍好遮(zhe)攔或(huo)圍繩(sheng),掛好標示牌,并派(pai)專(zhuan)人監護。
(3)試(shi)驗前,被試(shi)品表(biao)面應(ying)擦拭干凈,將(jiang)被試(shi)品的(de)外殼和非被試(shi)繞組可靠接地。被試(shi)品為新(xin)沖油(you)設(she)備時,應(ying)按《規程》規定使油(you)靜止一定時間再升壓,對110kV及(ji)以(yi)下(xia)的(de)充(chong)(chong)油(you)電(dian)力設(she)備,在注(zhu)滿油(you)后(hou)靜置時間應(ying)不少(shao)(shao)于(yu)24小時,對220kV及(ji)330kV的(de)充(chong)(chong)油(you)電(dian)力設(she)備,靜置時間應(ying)不少(shao)(shao)于(yu)48小時。
(4)接好試(shi)驗接線后,應由有經(jing)驗的人員檢查(cha),確(que)認無誤后方可升壓。
(5)升壓(ya)(ya)前(qian),首先檢查調壓(ya)(ya)器是否在(zai)零(ling)位(wei)。調壓(ya)(ya)器在(zai)零(ling)位(wei)方可升壓(ya)(ya)。
(6)升(sheng)壓(ya)(ya)過程中不(bu)僅(jin)要(yao)監視(shi)電(dian)壓(ya)(ya)表的(de)變化,還應監視(shi)電(dian)流(liu)表的(de)變化,以及(ji)被(bei)試品(pin)電(dian)流(liu)的(de)變化。升(sheng)壓(ya)(ya)時要(yao)均勻(yun)升(sheng)壓(ya)(ya),不(bu)能太快。升(sheng)至規定試驗電(dian)壓(ya)(ya)時,開(kai)始(shi)計算時間(jian),時間(jian)到后,緩(huan)慢均勻(yun)降下(xia)電(dian)壓(ya)(ya)。絕不(bu)允許(xu)不(bu)降壓(ya)(ya)就先跳開(kai)電(dian)源(yuan)開(kai)關(guan)。
(7)試驗中(zhong)發(fa)現表針擺動或(huo)被(bei)試品有異常(chang)聲響(xiang)、冒煙等應立(li)即降(jiang)下電壓(ya),拉(la)開電源,在(zai)高(gao)壓(ya)側掛上(shang)接地線后,再查明(ming)原因(yin)。
(8)耐壓試(shi)驗前后(hou)均應測量被試(shi)品(pin)的絕緣電阻。
2、操作(zuo)步(bu)驟
(1) 按試(shi)驗(yan)要求將控(kong)制(zhi)部分、試(shi)驗(yan)變(bian)壓器(qi)、被試(shi)品正(zheng)確接(jie)好線,必須(xu)可(ke)靠(kao)接(jie)地,請參考圖(tu)1、圖(tu)2、圖(tu)3、圖(tu)4、圖(tu)5。
(2) 根(gen)據試驗的要求,整定“時(shi)間繼(ji)電器(qi)”及“過流繼(ji)電器(qi)”。
A 時間繼電(dian)器設置:
T1,T2,T3,T4設置(zhi)0~9任意數字,T可設置(zhi)為H(小時),M(分鐘(zhong)),S(秒)。
根據試驗要(yao)求,在1S~99H內可以任意設置定時(shi)時(shi)間(jian)。
B 過(guo)流繼電器(qi)設置(zhi):
過(guo)流(liu)(liu)動作設定值=過(guo)流(liu)(liu)繼電(dian)器(qi)刻(ke)度盤讀數×測量(liang)變(bian)比×K,其中(zhong)K為(wei)(wei)電(dian)流(liu)(liu)倍(bei)率/切除(chu)開(kai)關(guan)的狀態(tai)值,分別為(wei)(wei)X1,X2,OFF,電(dian)流(liu)(liu)倍(bei)率/切除(chu)開(kai)關(guan)處于×1,×2位置(zhi)時(shi),K值分別為(wei)(wei)1、2,切換為(wei)(wei)OFF擋時(shi),K值為(wei)(wei)+∞。(注(zhu):不(bu)要(yao)使(shi)用OFF檔(dang),因為(wei)(wei)會(hui)使(shi)變(bian)壓(ya)器(qi)失去(qu)過(guo)流(liu)(liu)保(bao)護功能而導致(zhi)設備損(sun)壞。測量(liang)變(bian)比為(wei)(wei)電(dian)流(liu)(liu)互(hu)感(gan)(gan)器(qi)的變(bian)比,沒(mei)有電(dian)流(liu)(liu)互(hu)感(gan)(gan)器(qi)時(shi)為(wei)(wei)1)。
(3) 接入電源,此時,“電源燈(deng)”亮(liang),表(biao)示外部電源已引(yin)入。如“零(ling)(ling)位燈(deng)”亮(liang),表(biao)示調(diao)壓器(qi)在零(ling)(ling)位。如“零(ling)(ling)位燈(deng)”不亮(liang),應逆時針旋轉(zhuan)調(diao)節調(diao)壓器(qi)手柄(bing)至(zhi)“零(ling)(ling)位燈(deng)”亮(liang),表(biao)示可進行(xing)調(diao)壓操作。
(4)按(an)“啟(qi)動按(an)鈕”。此時(shi),“送電燈”,“電源燈”和(he)“零位燈”亮;進入送電狀(zhuang)態。
(5)以2kV/S勻速順時(shi)針(zhen)旋轉調壓器手(shou)柄(bing)至被試品規定的耐(nai)壓值(zhi),并密切(qie)注視電流(liu)(liu)表(直(zhi)流(liu)(liu)耐(nai)壓試驗時(shi),同時(shi)密切(qie)注視直(zhi)流(liu)(liu)微安表)。此時(shi),“電源燈(deng)”,“工(gong)作燈(deng)”亮;“零位燈(deng)”滅(mie)。
(6)根據試(shi)驗啟動“計時按鈕”,計時開(kai)始,并注(zhu)意(yi)被試(shi)品的情況。
(7)當耐壓計時到時,操作臺自動聲光報警。應立(li)即逆時針(zhen)旋轉調壓器手柄(bing)至(zhi)零(ling)位,按下停止(zhi)按鈕和解(jie)除計時按鈕自鎖狀態。此時“電源燈(deng)”, “零(ling)位燈(deng)”亮,“工(gong)作燈(deng)”滅。試驗(yan)即告(gao)完畢
(8)拔掉電源(yuan),拆除接線,試驗結束。
(9)在升壓(ya)(ya)或耐壓(ya)(ya)過(guo)(guo)程中,如發生(sheng)短(duan)路(lu)、閃(shan)絡、擊穿過(guo)(guo)流時,過(guo)(guo)流繼電器(qi)動作(zuo),切斷主回路(lu)。此時應將(jiang)調壓(ya)(ya)器(qi)逆時針旋轉至零(ling)位,切斷電源,并查明原因,并作(zuo)詳(xiang)細記錄。
(10)試驗(yan)完畢(bi),降壓,切斷(duan)電源后應用放**將被試品及(ji)試驗(yan)裝置本身充分(fen)放電。
七、產品維護
1、開(kai)箱驗收時,應檢查主(zhu)控(kong)回路接線是(shi)否松(song)動,調壓器電刷(shua)是(shi)否接觸(chu)良好;
2、長期不(bu)用時,使用前應用500V兆歐表測量(liang)絕(jue)緣電(dian)阻(zu),其(qi)阻(zu)值不(bu)低于0.5MΩ;
3、電源電壓應符合控制箱(臺)銘牌上的輸入(ru)電壓值;
4、本裝(zhuang)置設有過電流保護,出(chu)廠(chang)已調整為額定(ding)電流的50%。用于小負載時,應根據(ju)被試品的額定(ding)容量電流重新設定(ding);
5、使(shi)用完畢后,應關好控(kong)制箱(xiang)(臺)門,以保持控(kong)制箱(xiang)(臺)內部清潔。
八(ba)、注意事項
1、按(an)照您所進行的試驗接(jie)好工作(zuo)(zuo)線路。試驗變(bian)壓器的外殼以(yi)及(ji)操作(zuo)(zuo)系統的外殼必須(xu)(xu)可靠接(jie)地。試驗變(bian)壓器的高壓繞(rao)組的X端(duan)(高壓尾)以(yi)及(ji)測量繞(rao)組的F端(duan)必須(xu)(xu)可靠接(jie)地。
2、做串級試驗(yan)時,**級、第三級試驗(yan)變壓(ya)器(qi)的(de)(de)低(di)壓(ya)繞(rao)(rao)組成X端,測量繞(rao)(rao)組的(de)(de)F端以及(ji)高(gao)壓(ya)繞(rao)(rao)組的(de)(de)X端(高(gao)壓(ya)端)均接本級試驗(yan)變壓(ya)器(qi)具外(wai)殼(ke)。**級、第三級試驗(yan)變壓(ya)器(qi)的(de)(de)外(wai)殼(ke)必須通(tong)過(guo)絕緣支架接地。
3、接通(tong)(tong)電(dian)源(yuan)前,操作系統(tong)的(de)(de)(de)(de)調(diao)壓(ya)(ya)(ya)器必須(xu)調(diao)到(dao)零(ling)位后方(fang)可接通(tong)(tong)電(dian)源(yuan),合閘,開始(shi)升(sheng)(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)。從零(ling)開始(shi)勻(yun)速(su)旋轉調(diao)壓(ya)(ya)(ya)器手(shou)輪升(sheng)(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)。升(sheng)(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)方(fang)式有:快速(su)升(sheng)(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)法,即(ji)(ji)20s逐(zhu)級升(sheng)(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)法;慢(man)(man)速(su)升(sheng)(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)法,即(ji)(ji)60s逐(zhu)級升(sheng)(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)法;極慢(man)(man)速(su)升(sheng)(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)法供(gong)選用。電(dian)壓(ya)(ya)(ya)從零(ling)開始(shi)按一定(ding)的(de)(de)(de)(de)升(sheng)(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)方(fang)式和速(su)度(du)上升(sheng)(sheng)(sheng)(sheng)(sheng)到(dao)您所需(xu)(xu)的(de)(de)(de)(de)額(e)定(ding)試(shi)驗(yan)電(dian)壓(ya)(ya)(ya)的(de)(de)(de)(de)75%后,再以每秒2%額(e)定(ding)試(shi)驗(yan)電(dian)壓(ya)(ya)(ya)的(de)(de)(de)(de)速(su)度(du)升(sheng)(sheng)(sheng)(sheng)(sheng)到(dao)您所需(xu)(xu)的(de)(de)(de)(de)試(shi)驗(yan)電(dian)壓(ya)(ya)(ya),并密切注意測量儀表的(de)(de)(de)(de)及被試(shi)品的(de)(de)(de)(de)情況(kuang)。升(sheng)(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)過程中(zhong)或試(shi)驗(yan)過程中(zhong)如發現(xian)測量儀表的(de)(de)(de)(de)指(zhi)示及被試(shi)品情況(kuang)異常,應立(li)即(ji)(ji)降壓(ya)(ya)(ya),切斷電(dian)源(yuan),查明(ming)情況(kuang)。
4、試驗完畢后,應在數秒內勻速的(de)將(jiang)調(diao)壓器返回至零(ling)位,然(ran)后切(qie)斷電源。本產品(pin)不(bu)得超過額定參數使用。
5、使(shi)用本產(chan)品做高壓(ya)試驗(yan)時,除熟悉本說明(ming)書外,還必須嚴格(ge)執行國(guo)家有關標準(zhun)和(he)操作(zuo)規程。可參照GB311.1 – 97《高壓(ya)輸變設(she)備(bei)的絕緣配(pei)合,高壓(ya)試驗(yan)技術》;《電氣設(she)備(bei)預防性試驗(yan)規程》等
一、概述
智能(neng)耐(nai)壓試(shi)驗(yan)裝置是根據國家*新電(dian)力行(xing)業標(biao)準而(er)設計的、性能(neng)先進的智能(neng)型耐(nai)壓試(shi)驗(yan)設備,用(yong)于(yu)對各種電(dian)器產品(pin)、電(dian)氣元件、絕(jue)(jue)(jue)(jue)緣(yuan)材(cai)料等進行(xing)規定電(dian)壓下的絕(jue)(jue)(jue)(jue)緣(yuan)強度試(shi)驗(yan),以考核產品(pin)的絕(jue)(jue)(jue)(jue)緣(yuan)水平,發現被試(shi)品(pin)的絕(jue)(jue)(jue)(jue)緣(yuan)缺陷,衡量過電(dian)壓的能(neng)力。廣泛應用(yong)于(yu)電(dian)工制造部(bu)門(men)(men)、電(dian)力運行(xing)部(bu)門(men)(men)、科研單位(wei)和高等院校。
二、產品特點(dian)
1. 320×240液晶(jing)顯示器、高速熱(re)敏打印機。
2. 高壓(ya)電(dian)(dian)壓(ya)、高壓(ya)電(dian)(dian)流、低壓(ya)電(dian)(dian)壓(ya)、低壓(ya)電(dian)(dian)流4路測量方式(shi),高精度傳感器和高性能(neng)14位AD采集芯片。
3. 人機對話全(quan)鍵盤操作方(fang)(fang)式(shi),智能化工作全(quan)過程,任選自動方(fang)(fang)式(shi)和手動方(fang)(fang)式(shi)。
4. 實時顯示(shi)(shi)高(gao)壓電(dian)壓、高(gao)壓電(dian)流、低壓電(dian)壓、低壓電(dian)流,時間及耐壓結(jie)果,顯示(shi)(shi)直觀明了。
5. 完善的過(guo)(guo)壓(ya)、過(guo)(guo)流保護,任意設(she)定輸出電(dian)(dian)壓(ya)、高(gao)壓(ya)電(dian)(dian)流上限、低壓(ya)電(dian)(dian)流上限和計時時間(jian)。
6. 具有(you)回(hui)零(ling)檢測功能,回(hui)零(ling)確(que)定后才(cai)可進行(xing)試驗,**可靠。
7. 具有絕(jue)緣(yuan)電阻測(ce)試(shi)功能,直接(jie)反(fan)映被試(shi)品(pin)絕(jue)緣(yuan)強(qiang)度(du)。
8. 逼近式調壓算法,到(dao)達(da)設定電壓后自動(dong)耐壓計(ji)(ji)時(shi),計(ji)(ji)時(shi)結(jie)束后自動(dong)降壓回零。
9. 超(chao)過設定高(gao)壓電流或(huo)低壓電流時自動切斷(duan)電壓輸出,降壓回零(ling),并(bing)發生聲光報警。
10. 精良的軟硬件(jian)抗干擾(rao)設計,多種抗干擾(rao)手段,適應惡劣電磁環境。
11. 自動(dong)錯誤診(zhen)斷,易于發現(xian)和解決問題。
12. 可選(xuan)配無線遙(yao)控控制功能、遠(yuan)程通信、門聯(lian)鎖警鈴、外接(jie)分壓器校驗接(jie)口等。
三、設備(bei)組成
1、選型配(pei)置
標準配置
|
□ 分體式
|
操作(zuo)部分(fen):
□箱式(不大(da)于5kVA) / □臺式
容量: kVA(小于200kVA)
輸(shu)入:□AC220V / □AC380V
|
試驗變(bian)壓器:
□交流 / □交直流
□油(you)變(bian)(bian) / □干變(bian)(bian) / □氣變(bian)(bian)
容量: kVA(小于200kVA)
輸出:AC kV(小于300kVA)
|
□ 一體式
|
□箱(xiang)式(不大于20kV) / □臺式(不大于30kV)
容量: kVA(小于300kVA)
輸入(ru):□AC220V / □AC380V 輸出:AC kV(不(bu)大于30kV)
|
客戶選配
|
□標準高(gao)壓(ya)(ya)分壓(ya)(ya)器
|
□保護球(qiu)隙
|
□直流微安表
|
□放**
|
□保護(hu)水阻
|
□高(gao)壓濾波電容
|
其它:
|
2、對應實物
四、技(ji)術(shu)指標
1、使用條(tiao)件:
(1)工作場所應無嚴重(zhong)影(ying)響(xiang)絕(jue)緣的氣體(ti)、蒸汽、化學性(xing)塵埃及其它爆炸性(xing)和腐蝕性(xing)介質(zhi)。
(2)環境溫度 -20~+50℃
(3)環(huan)境(jing)濕度 ≤85% RH(無(wu)凝結水(shui))
2、控制箱(臺)參(can)數(shu):(常規參(can)數(shu)見下表)
(1)計(ji)時范(fan)圍(wei):0-999S
(3)電壓精(jing)度 ≤1.5% ±1個字(F.S)
(4)電流精度 ≤1.5% ±1個(ge)字(F.S)
規格
|
容(rong)量
|
輸 入 電 源
|
輸(shu) 出 電 壓(ya)
|
重量(liang)(kg)
|
相數
|
(V)
|
(A)
|
(V)
|
(A)
|
2/220
|
2
|
1
|
220
|
10
|
0-250
|
8
|
14
|
3/220
|
3
|
1
|
220
|
15
|
0-250
|
12
|
16
|
5/220
|
5
|
1
|
220
|
25
|
0-250
|
20
|
18
|
10/220
|
10
|
1
|
220
|
50
|
0-250
|
40
|
80
|
15/380
|
15
|
2
|
380
|
37.5
|
0-430
|
34.8
|
90
|
20/380
|
20
|
2
|
380
|
50
|
0-430
|
46.5
|
100
|
25/380
|
25
|
2
|
380
|
62.5
|
0-430
|
58.1
|
120
|
30/380
|
30
|
2
|
380
|
75
|
0-430
|
69.7
|
140
|
50/380
|
50
|
2
|
380
|
125
|
0-430
|
116.2
|
160
|
100/380
|
100
|
2
|
380
|
250
|
0-430
|
232.5
|
250
|
說(shuo)明:如有特殊參數要求,可按用(yong)戶的技(ji)術參數進(jin)行設計制作。
3、試驗變壓(ya)器參數:(常規參數見下(xia)表)
規格
|
容(rong)量
kVA
|
低壓側(ce)
|
高壓側
|
高壓(ya)側(ce)(交直流變壓(ya)器)
|
測量變(bian)比
|
60分鐘溫(wen)升℃
|
阻抗電(dian)壓(ya)%
|
空(kong)載電(dian)流
%
|
質量
kg
|
電壓(ya)
V
|
電(dian)流(liu)
A
|
交流輸出
|
直流輸出
|
電壓kV
|
電流
|
電壓kV
|
電流
|
1.5/50
|
1.5
|
200
|
7.5
|
50
|
30
|
70
|
21.4
|
500
|
50
|
10
|
<4
|
19.5
|
3/50
|
3
|
200
|
15
|
50
|
60
|
70
|
42.9
|
500
|
50
|
10
|
<4
|
27
|
5/50
|
5
|
200
|
25
|
50
|
100
|
70
|
71.4
|
500
|
50
|
10
|
<4
|
52
|
10/50
|
10
|
200
|
50
|
50
|
200
|
70
|
142.9
|
500
|
50
|
10
|
<4
|
80
|
15/50
|
15
|
400
|
37.5
|
50
|
300
|
70
|
214.3
|
500
|
50
|
8
|
<4
|
120
|
20/50
|
20
|
400
|
50
|
50
|
400
|
70
|
285.7
|
500
|
50
|
8
|
<4
|
140
|
30/50
|
30
|
400
|
75
|
50
|
600
|
70
|
428.6
|
500
|
50
|
8
|
<4
|
155
|
50/50
|
50
|
400
|
125
|
50
|
1000
|
70
|
714.3
|
500
|
50
|
8
|
<4
|
184
|
10/100
|
10
|
200
|
50
|
100
|
100
|
140
|
71.4
|
1000
|
50
|
10
|
<4
|
135
|
15/100
|
15
|
400
|
37.5
|
100
|
150
|
140
|
107.1
|
1000
|
50
|
8
|
<4
|
150
|
20/100
|
20
|
400
|
50
|
100
|
200
|
140
|
142.9
|
1000
|
50
|
8
|
<4
|
215
|
30/100
|
30
|
400
|
75
|
100
|
300
|
140
|
214.3
|
1000
|
50
|
8
|
<4
|
250
|
50/100
|
50
|
400
|
125
|
100
|
500
|
140
|
357.1
|
1000
|
50
|
8
|
<4
|
290
|
10/150
|
10
|
200
|
50
|
100
|
66.7
|
140
|
47.6
|
1500
|
50
|
10
|
<4
|
180
|
15/150
|
15
|
400
|
37.5
|
150
|
100
|
210
|
71.4
|
1500
|
50
|
8
|
<4
|
200
|
20/150
|
30
|
400
|
50
|
150
|
133.3
|
210
|
95.2
|
1500
|
50
|
8
|
<4
|
220
|
30/150
|
30
|
400
|
75
|
150
|
200
|
210
|
142.9
|
1500
|
50
|
8
|
<4
|
280
|
50/150
|
50
|
400
|
125
|
150
|
333.3
|
210
|
238.1
|
1500
|
50
|
8
|
<4
|
340
|
說明:如有特殊參數(shu)要求,可(ke)按用戶的技術參數(shu)進行設計制作。
上表的重量以油浸式試(shi)驗變壓器(qi)為例(li),干式試(shi)驗變壓器(qi)和(he)充(chong)氣(qi)式試(shi)驗變壓器(qi)稍有不(bu)同。
五、接線及工(gong)作原理
1、調壓部分(fen)接線及原理
調壓(ya)(ya)(ya)部分由控(kong)制(zhi)部分和(he)試驗變壓(ya)(ya)(ya)器(qi)組成。控(kong)制(zhi)部分是由接觸式(shi)調壓(ya)(ya)(ya)器(qi)、單片機控(kong)制(zhi)系統、液晶、打(da)印(yin)機、信號測量、電路保(bao)護組成。試驗變壓(ya)(ya)(ya)器(qi)由低壓(ya)(ya)(ya)繞組、高壓(ya)(ya)(ya)繞組、儀表繞組三部分組成。
試驗變(bian)壓器為交直(zhi)流(liu)兩用時(shi)(shi),試驗變(bian)壓器配置了高(gao)壓硅堆(油(you)變(bian)、氣變(bian)為內置,干(gan)變(bian)為外置),高(gao)壓可(ke)輸(shu)出交流(liu)和直(zhi)流(liu)。輸(shu)出交流(liu)時(shi)(shi),要(yao)求接入短路桿(油(you)變(bian)、氣變(bian))或(huo)去掉外置硅堆(干(gan)變(bian));輸(shu)出直(zhi)流(liu)時(shi)(shi),要(yao)求擰出短路桿(油(you)變(bian)、氣變(bian))或(huo)加上外置硅堆(干(gan)變(bian))
通過接(jie)入工(gong)頻(pin)電源(yuan),調(diao)(diao)節調(diao)(diao)壓器,以獲得所需(xu)要的試驗高壓電壓值。其工(gong)作原理見圖1:
2、試驗部分接(jie)線及原理(li)
做(zuo)耐(nai)壓(ya)(ya)試(shi)驗(yan)時,控制部分(fen)、變壓(ya)(ya)器(qi)的接地(di)端(duan)及高(gao)壓(ya)(ya)尾必須(xu)可靠接地(di)。有(you)條件的情況(kuang)下,做(zuo)工頻(pin)耐(nai)壓(ya)(ya)試(shi)驗(yan)請加(jia)上限流電(dian)阻(zu)、標準高(gao)壓(ya)(ya)分(fen)壓(ya)(ya)器(qi)、球隙(xi)保護電(dian)阻(zu)及保護球隙(xi),如圖3。
做(zuo)直流耐壓試(shi)驗(yan)請另外加上(shang)微安(an)(an)表,微安(an)(an)表必須接在硅堆(dui)和被試(shi)器之(zhi)間(jian),油變(bian)或氣變(bian)一般(ban)擰在高壓頭上(shang)面(要求(qiu)擰出短路桿(gan)),干變(bian)擰在外置硅堆(dui)上(shang)面;為了更準確顯示高壓直流泄(xie)漏電流,請將分壓器的高壓線接在微安(an)(an)表和硅堆(dui)之(zhi)間(jian),(油變(bian)、氣變(bian))如(ru)圖4,(干變(bian))如(ru)圖5。
耐壓(ya)試驗中(zhong)限流電(dian)阻R1應根據試驗變壓(ya)器的(de)額定容(rong)量(liang)來選擇。如高壓(ya)側(ce)額定輸(shu)出(chu)電(dian)流在100~300mA時(shi),可取(qu)0.5~1Ω/V(試驗電(dian)壓(ya));高壓(ya)側(ce)額定輸(shu)出(chu)電(dian)流為(wei)1A以上時(shi),可取(qu)1Ω/V(試驗電(dian)壓(ya))。常用水(shui)電(dian)阻作(zuo)為(wei)限流電(dian)阻,管子(zi)長度可按150kV/m考慮(lv),管子(zi)粗細應具有足(zu)夠的(de)熱容(rong)量(liang)(水(shui)阻液配制方法:用蒸(zheng)餾水(shui)加入適量(liang)硫(liu)酸銅配制成各(ge)種不同的(de)阻值)。
球間(jian)隙及保(bao)護電(dian)阻:當電(dian)壓(ya)(ya)超過球間(jian)隙整定值時(一般(ban)取試(shi)驗電(dian)壓(ya)(ya)的110%~120%),球間(jian)隙放電(dian),對被試(shi)品起(qi)到保(bao)護作用。球間(jian)隙保(bao)護電(dian)阻可按1Ω/V(試(shi)驗電(dian)壓(ya)(ya))選取。
在工頻(pin)耐壓(ya)(ya)(ya)試(shi)(shi)驗(yan)中,低(di)電(dian)壓(ya)(ya)(ya)側測量電(dian)壓(ya)(ya)(ya)(儀表(biao)電(dian)壓(ya)(ya)(ya))不是非常準(zhun)確(que)(que)的(de)(de),其原(yuan)因(yin)是由于(yu)(yu)試(shi)(shi)驗(yan)變壓(ya)(ya)(ya)器(qi)(qi)存在著(zhu)(zhu)漏抗,在這個漏抗上(shang)(shang)必(bi)然存在著(zhu)(zhu)壓(ya)(ya)(ya)降(jiang)或(huo)(huo)容(rong)升(sheng),使試(shi)(shi)品(pin)上(shang)(shang)的(de)(de)電(dian)壓(ya)(ya)(ya)低(di)于(yu)(yu)或(huo)(huo)高(gao)于(yu)(yu)低(di)壓(ya)(ya)(ya)側測量電(dian)壓(ya)(ya)(ya)表(biao)上(shang)(shang)反映出來的(de)(de)電(dian)壓(ya)(ya)(ya)。工頻(pin)耐壓(ya)(ya)(ya)試(shi)(shi)驗(yan)時(shi),被試(shi)(shi)品(pin)上(shang)(shang)的(de)(de)電(dian)壓(ya)(ya)(ya)高(gao)于(yu)(yu)試(shi)(shi)驗(yan)變壓(ya)(ya)(ya)器(qi)(qi)的(de)(de)輸出電(dian)壓(ya)(ya)(ya),也(ye)就是所謂容(rong)升(sheng)現象(xiang)。感應耐壓(ya)(ya)(ya)試(shi)(shi)驗(yan)時(shi),試(shi)(shi)驗(yan)變壓(ya)(ya)(ya)器(qi)(qi)的(de)(de)漏抗必(bi)然存在著(zhu)(zhu)壓(ya)(ya)(ya)降(jiang)。為了準(zhun)確(que)(que)測量被試(shi)(shi)品(pin)上(shang)(shang)所施加的(de)(de)電(dian)壓(ya)(ya)(ya),因(yin)此常在高(gao)壓(ya)(ya)(ya)側接入標準(zhun)高(gao)壓(ya)(ya)(ya)分壓(ya)(ya)(ya)器(qi)(qi)來測量電(dian)壓(ya)(ya)(ya)。
六、操作要(yao)點
1、試(shi)(shi)(shi)驗前,應(ying)了解(jie)被試(shi)(shi)(shi)品(pin)的(de)試(shi)(shi)(shi)驗電壓,同時了解(jie)被試(shi)(shi)(shi)品(pin)的(de)其他試(shi)(shi)(shi)驗項目(mu)及以前的(de)試(shi)(shi)(shi)驗結果。若被試(shi)(shi)(shi)品(pin)有(you)缺陷(xian)或異常,應(ying)在消除后(hou)再進(jin)行(xing)耐壓試(shi)(shi)(shi)驗。
2、試驗現場應圍好遮攔或圍繩,掛好標示牌(pai),并派(pai)專(zhuan)人監護。
3、試(shi)驗前,被試(shi)品(pin)表面(mian)應(ying)擦(ca)拭干凈,將被試(shi)品(pin)的(de)外(wai)殼和(he)非被試(shi)繞組可靠接(jie)地。被試(shi)品(pin)為新沖油設(she)備時(shi),應(ying)按《規程》規定使油靜止(zhi)一定時(shi)間(jian)再(zai)升壓,對110kV及以(yi)下的(de)充(chong)油電(dian)力設(she)備,在注滿油后(hou)靜置(zhi)時(shi)間(jian)應(ying)不少于24小時(shi),對220kV及330kV的(de)充(chong)油電(dian)力設(she)備,靜置(zhi)時(shi)間(jian)應(ying)不少于48小時(shi)。
4、接(jie)好試驗接(jie)線后,應由有經驗的人員檢查,確認(ren)無誤后方可升壓。
5、升壓(ya)(ya)前,首先檢查調(diao)壓(ya)(ya)器是否在零位。調(diao)壓(ya)(ya)器在零位方可(ke)升壓(ya)(ya)。
6、升壓(ya)(ya)(ya)(ya)過程中(zhong)不(bu)(bu)(bu)僅要監視(shi)電(dian)壓(ya)(ya)(ya)(ya)的(de)變(bian)(bian)化(hua),還(huan)應監視(shi)電(dian)流的(de)變(bian)(bian)化(hua),以及被試品(pin)泄(xie)漏電(dian)流的(de)變(bian)(bian)化(hua)。升壓(ya)(ya)(ya)(ya)時(shi)要均(jun)勻(yun)升壓(ya)(ya)(ya)(ya),不(bu)(bu)(bu)能(neng)太快。升至規(gui)定試驗電(dian)壓(ya)(ya)(ya)(ya)時(shi),開(kai)始計時(shi),時(shi)間到后(hou),緩慢均(jun)勻(yun)降下(xia)電(dian)壓(ya)(ya)(ya)(ya)。絕不(bu)(bu)(bu)允(yun)許不(bu)(bu)(bu)降壓(ya)(ya)(ya)(ya)就先跳開(kai)電(dian)源(yuan)開(kai)關。
7、試(shi)(shi)(shi)驗中發現被試(shi)(shi)(shi)品有異常聲響、冒煙等應立即降下電(dian)(dian)壓(ya),拉開電(dian)(dian)源,在高壓(ya)側掛上接地線后,再查明原因(yin)。耐壓(ya)試(shi)(shi)(shi)驗前后均應測量被試(shi)(shi)(shi)品的絕緣(yuan)電(dian)(dian)阻(zu)。
七、面(mian)板功能(neng)說明(ming)
打印(yin)機(ji):打印(yin)機(ji)是(shi)熱敏打印(yin)機(ji),當試(shi)驗(yan)完(wan)成后按(an)鍵(jian)盤上的“打印(yin)”按(an)鈕打印(yin)試(shi)驗(yan)結果。
RS232:RS232是(shi)(shi)與(yu)計算機(ji)相連的串口(kou)通信接(jie)(jie)口(kou),是(shi)(shi)用戶(hu)選(xuan)配(pei)接(jie)(jie)口(kou),本裝置沒有(you)配(pei)置這個接(jie)(jie)口(kou)。
LCD對比(bi)度(du)(du):因為液(ye)晶顯示屏在溫度(du)(du)和(he)光線有所不同時稍有些變化(hua),可以通過LCD對比(bi)度(du)(du)調(diao)節背光到適合亮度(du)(du)。
液(ye)晶: 320x240像素(su)點陣白(bai)色背(bei)光液(ye)晶,在強光和陰暗環境下都十分清楚(chu)。
指示燈(deng)(deng):由啟動燈(deng)(deng)、零位燈(deng)(deng)、指示燈(deng)(deng)三個燈(deng)(deng)組成,啟動燈(deng)(deng)和(he)警(jing)示燈(deng)(deng)是(shi)高亮七彩(cai)燈(deng)(deng)。
操(cao)作提示:有(you)一(yi)些簡短(duan)的提示語句和安裝(zhuang)接線圖。
緊急開關:在(zai)緊急情(qing)況(kuang)下(xia)按此開關,即可以(yi)切斷變(bian)壓器電(dian)源,也可以(yi)切斷工(gong)作電(dian)源。(箱(xiang)式安裝在(zai)面板上,臺式安裝在(zai)柜體上)
鍵盤:由上、下、左(zuo)、右、設(she)置(zhi)、打印、確定、取消8個鍵組(zu)成,是用戶和設(she)備交互的終端。
電源開關:工作(zuo)電源,帶通電指示燈(deng)。
八、軟(ruan)件使用說明(ming)
按試(shi)驗要(yao)求將控制部分、試(shi)驗變壓器、被試(shi)品正確接好線(xian),必須可靠接地,請參考圖1、圖2、圖3、圖4、圖5。
1、開(kai)機使用
開機(ji)處(chu)于(yu)“歡迎(ying)界面”,如圖7:
根據鍵(jian)盤的示圖8,按上↑、下(xia)↓、左(zuo)←,右(you)→可(ke)以切換“自動耐壓(ya)試驗(yan)”或(huo)“手動耐壓(ya)試驗(yan)”,在(zai)“自動試驗(yan)”或(huo)“手動試驗(yan)”里(li)面選擇“交流試驗(yan)方(fang)式”或(huo)“直流試驗(yan)方(fang)式”。如圖9
說明:
(1)當配置的是交(jiao)直流兩用(yong)控(kong)制部分時(shi)(shi),使用(yong)直流輸(shu)出時(shi)(shi)軟(ruan)件(jian)(jian)操作請進入直流試(shi)驗方式(shi),交(jiao)流輸(shu)出時(shi)(shi)軟(ruan)件(jian)(jian)操作請進入交(jiao)流試(shi)驗方式(shi),如(ru)果選擇錯誤會導致儀器顯示(shi)電壓會和輸(shu)出實際電壓不一(yi)致。
(2)當(dang)配置的是交直(zhi)流(liu)兩用(yong)變(bian)壓器時(shi),使(shi)用(yong)直(zhi)流(liu)時(shi)請將(jiang)變(bian)壓器的短路(lu)桿取出,當(dang)使(shi)用(yong)交流(liu)時(shi)請將(jiang)短路(lu)桿插入(ru)擰緊。
(3)如果配置的是交流(liu)控制(zhi)部分時,軟件界面里就沒有交直(zhi)流(liu)試驗方式(如圖(tu)9)的選擇項。
選中試驗方式后(hou),按確定可(ke)以進(jin)入主界面,如圖10:
動態(tai)顯示(shi)區:一直(zhi)處(chu)于(yu)采集信(xin)號,并顯示(shi)高(gao)(gao)壓(ya)(ya)電壓(ya)(ya)、高(gao)(gao)壓(ya)(ya)電流(liu)、低(di)(di)壓(ya)(ya)電壓(ya)(ya)、低(di)(di)壓(ya)(ya)電流(liu)。
結果顯示(shi)(shi)區:如果試(shi)驗沒(mei)有(you)被擊穿(chuan)時,顯示(shi)(shi)平均(jun)高壓(ya)電(dian)壓(ya),平均(jun)高壓(ya)電(dian)流,平均(jun)低(di)壓(ya)電(dian)壓(ya),平均(jun)低(di)壓(ya)電(dian)流,絕緣電(dian)阻;否之(zhi),顯示(shi)(shi)峰值(zhi)電(dian)壓(ya),峰值(zhi)電(dian)流,低(di)壓(ya)電(dian)壓(ya),低(di)壓(ya)電(dian)流。
設置(zhi)數(shu)據(ju)區:設置(zhi)試驗中需要的參數(shu)數(shu)據(ju)輸出電壓(ya)(ya)為(wei)(wei)在自(zi)動方式(shi)下的升壓(ya)(ya)目標(biao)耐(nai)(nai)壓(ya)(ya)值耐(nai)(nai)壓(ya)(ya)時間(jian)為(wei)(wei)耐(nai)(nai)壓(ya)(ya)過(guo)程(cheng)的時間(jian)長度(du)電流上限為(wei)(wei)高壓(ya)(ya)電流峰值的上限,高壓(ya)(ya)電流超過(guo)電流上限將認為(wei)(wei)擊(ji)穿過(guo)流保護為(wei)(wei)低壓(ya)(ya)電流峰值的上限,低壓(ya)(ya)電流超過(guo)過(guo)流保護將認為(wei)(wei)擊(ji)穿
信(xin)息(xi)顯示區:顯示試驗過程中的(de)試驗狀態和提示信(xin)息(xi)。
試驗操作區:選(xuan)擇設置、試驗、回零命令。
2、設置參數
在主(zhu)界面(mian)上(shang),選(xuan)中“設(she)置”,然(ran)后按確定(ding)后進入設(she)置界面(mian),如圖11:
按左←,右→時(shi)切(qie)換(huan)光標(biao)移動位置,按上↑、下↓時(shi)更(geng)改(gai)光標(biao)位置數據的(de)值(zhi)。光標(biao)位置和設(she)(she)置的(de)數值(zhi)全部可以(yi)自動循環,前且在使用(yong)時(shi)有(you)默認的(de)標(biao)準值(zhi)。如果所有(you)的(de)參數都設(she)(she)置完成,按取消退(tui)出設(she)(she)置回(hui)到主界面開始(shi)狀態。
3、手動(dong)試驗
零(ling)位檢查—當選中“試驗(yan)(yan)(yan)”后,按(an)確定(ding)就進入提示試驗(yan)(yan)(yan)狀態(tai)。如果調(diao)壓器不在(zai)零(ling)位,將(jiang)提示“試驗(yan)(yan)(yan)前請先(xian)回(hui)零(ling)”,退出試驗(yan)(yan)(yan)并且切換到回(hui)零(ling)命令。
試驗(yan)(yan)過程—回(hui)零(ling)確認后,可(ke)以進行試驗(yan)(yan)。選(xuan)中“試驗(yan)(yan)”后按確定,接(jie)觸器合閘(zha),這時輸出電壓幾(ji)乎(hu)為0,如圖12:
按上↑,高壓電壓將不斷升(sheng)壓,松開(kai)就停止升(sheng)壓,如果到(dao)上限就提示滿量程;
按下(xia)↓,高壓(ya)電壓(ya)將不斷降壓(ya),松開就(jiu)停止降壓(ya),如(ru)果(guo)到下(xia)限就(jiu)提示已回零(ling);
按(an)計(ji)時←,計(ji)時開始工作,到耐壓時間計(ji)時結(jie)束完(wan)成(cheng)試驗;
按取消→,取消試驗過程;
在升壓(ya)(ya)(ya)(ya)(ya)過(guo)程中,如(ru)果高壓(ya)(ya)(ya)(ya)(ya)電流(liu)峰值(zhi)(zhi)超過(guo)“電流(liu)上限”值(zhi)(zhi)或低壓(ya)(ya)(ya)(ya)(ya)電流(liu)峰值(zhi)(zhi)超過(guo)“過(guo)流(liu)保護”值(zhi)(zhi)將認為被(bei)試品被(bei)擊穿,接(jie)觸器(qi)(qi)立刻(ke)分(fen)閘并(bing)顯(xian)示(shi)試驗結果,包(bao)括峰值(zhi)(zhi)電壓(ya)(ya)(ya)(ya)(ya)、峰值(zhi)(zhi)電流(liu)、低壓(ya)(ya)(ya)(ya)(ya)電流(liu)等,調(diao)(diao)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)開始回零,回零完(wan)成試驗結束(shu)。如(ru)果在耐壓(ya)(ya)(ya)(ya)(ya)過(guo)程中,高壓(ya)(ya)(ya)(ya)(ya)電流(liu)和低壓(ya)(ya)(ya)(ya)(ya)電流(liu)峰值(zhi)(zhi)沒有超設置(zhi)上限值(zhi)(zhi),認為被(bei)試品未擊穿,結果顯(xian)示(shi)區就顯(xian)示(shi)耐壓(ya)(ya)(ya)(ya)(ya)電壓(ya)(ya)(ya)(ya)(ya)、高壓(ya)(ya)(ya)(ya)(ya)電流(liu)、低壓(ya)(ya)(ya)(ya)(ya)電流(liu)、絕緣電阻等,調(diao)(diao)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)開始回零,回零完(wan)成后(hou)接(jie)觸器(qi)(qi)分(fen)閘試驗結束(shu)。
4、自動試驗
自動試驗(yan)和手動試驗(yan)的試驗(yan)過程(cheng)類似(si),首先也進(jin)行回零(ling)檢查,確認后進(jin)入如下(xia)界面,如圖13:
按上方(fang)法切換到(dao)“開始”確定后(hou)進行(xing)試驗,與手動試驗不同之處就是升(sheng)壓(ya)過程將自(zi)動升(sheng)壓(ya)到(dao)“輸出電壓(ya)”值,然(ran)后(hou)進行(xing)計(ji)時。
升(sheng)壓過程為逼近方式,首先升(sheng)到(dao)到(dao)接近目標值,然后再(zai)進行(xing)微調(diao),保證高壓電(dian)壓值幾乎(hu)為輸出電(dian)壓值。
5、功能選擇
按(an)鍵盤(pan)上的“設(she)置”就進入功能界面,如圖14:
進入功能(neng)界(jie)(jie)面后,可以選(xuan)擇“時鐘設置”、“注意(yi)事項(xiang)”等界(jie)(jie)面。
時鐘設(she)置:設(she)置時鐘的時間,為打印報(bao)表提供時間依據。
注意事項(xiang):為(wei)用戶提供一(yi)些操作(zuo)規(gui)范和**注意事項(xiang)。
6、打印
按(an)鍵盤“打印”按(an)鍵可(ke)以打印試(shi)驗(yan)果,在(zai)此不贅述。
七(qi)、產品維護
1、開箱驗收(shou)時(shi),應(ying)檢查主控回路接線(xian)是(shi)否(fou)松動,調(diao)壓(ya)器電(dian)刷是(shi)否(fou)接觸良(liang)好。
2.、長(chang)期不用時(shi),使用前應用500V兆歐表(biao)測(ce)量絕緣電阻(zu),其阻(zu)值不低于0.5MΩ。
3、電(dian)源電(dian)壓應符合控制(zhi)箱(臺)說明書(shu)上的輸入(ru)電(dian)壓值(zhi)要求。
4、本控制(zhi)箱(臺)設有過電(dian)流(liu)保(bao)護,出廠已調整為(wei)額定電(dian)流(liu)的50%。用于小負(fu)載時,應根(gen)據被(bei)試品(pin)的額定容量電(dian)流(liu)重新設定;
5、使用完畢后,應關好(hao)控制箱(臺)門蓋,以保持內(nei)部清(qing)潔。
八(ba)、注意事項
1、按照您(nin)所進行的(de)(de)試(shi)驗接好工作線路。試(shi)驗變壓器的(de)(de)外(wai)(wai)殼以及操作系統的(de)(de)外(wai)(wai)殼必(bi)須(xu)可靠接地。試(shi)驗變壓器的(de)(de)測(ce)量繞組的(de)(de)F端和外(wai)(wai)殼必(bi)須(xu)可靠接地。
2、做串(chuan)級(ji)(ji)試驗時,**級(ji)(ji)、第三級(ji)(ji)試驗變壓器(qi)的低壓繞組成X端,測量(liang)繞組的F端以及高壓繞組的X端(高壓端)均(jun)接本(ben)級(ji)(ji)試驗變壓器(qi)具(ju)外殼。**級(ji)(ji)、第三級(ji)(ji)試驗變壓器(qi)的外殼必須通(tong)過(guo)絕緣支架接地。
接(jie)通電源前,控制箱(臺)的調壓器必(bi)須調到(dao)零(ling)位(wei)后方可(ke)接(jie)通電源,合閘(zha),開始升壓。
3、從零(ling)開始勻速(su)旋轉(zhuan)調壓(ya)(ya)(ya)(ya)(ya)器手(shou)輪升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)。升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)方式有:快速(su)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)法(fa),即(ji)(ji)20s逐級升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)法(fa);慢速(su)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)法(fa),即(ji)(ji)60s逐級升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)法(fa);極慢速(su)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)法(fa)供選用。電(dian)壓(ya)(ya)(ya)(ya)(ya)從零(ling)開始按一定(ding)的(de)(de)(de)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)方式和速(su)度上(shang)升(sheng)(sheng)(sheng)(sheng)到您所需的(de)(de)(de)額(e)定(ding)試驗電(dian)壓(ya)(ya)(ya)(ya)(ya)的(de)(de)(de)75%后,再以每秒2%額(e)定(ding)試驗電(dian)壓(ya)(ya)(ya)(ya)(ya)的(de)(de)(de)速(su)度升(sheng)(sheng)(sheng)(sheng)到您所需的(de)(de)(de)試驗電(dian)壓(ya)(ya)(ya)(ya)(ya),并密切注意測量儀表(biao)的(de)(de)(de)及被(bei)試品的(de)(de)(de)情況(kuang)。升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)過(guo)程(cheng)中(zhong)或試驗過(guo)程(cheng)中(zhong)如發現測量儀表(biao)的(de)(de)(de)指示(shi)及被(bei)試品情況(kuang)異常,應立即(ji)(ji)降壓(ya)(ya)(ya)(ya)(ya),切斷(duan)電(dian)源(yuan),查(cha)明情況(kuang)。
4、試驗完畢后,應在等調壓器返回至(zhi)零(ling)位,然(ran)后切斷電(dian)源。
5、本產品不(bu)得超過額定參數使用。
6、使用本產品做高壓試驗(yan)時,除(chu)熟悉本說明書外(wai),還(huan)必須嚴格(ge)執(zhi)行國家有(you)關標準和(he)操作規(gui)程。可(ke)參照GB311.1 – 97《高壓輸(shu)變設(she)備的(de)絕緣(yuan)配合,高壓試驗(yan)技術(shu)》;《電氣設(she)備預(yu)防(fang)性試驗(yan)規(gui)程》等。
7、控制(zhi)箱(xiang)(臺)應與試驗變壓器(qi)配套(tao)使用,控制(zhi)箱(xiang)(臺)的使用方法,請詳(xiang)細參閱(yue)控制(zhi)器(qi)的使用說明書。